Operation

12.Adjust the needle valve to set the pump cycle rate at 1 stroke every 15 seconds.

13.Turn the heater dial to 3. Whenever the heater set- ting is changed, allow the fluid to circulate and sta- bilize before checking the temperature (about IO minutes) .

A CAUTION

Be sure the fluid is circulating whenever the heater is on to reduce the risk of damage to the fluid or the heater.

14.Follow the fluid manufacturer’s recommendations for temperature, and adjust the heater accordingly. If unknown, set the temperature to 110°F (43°C) at the outlet thermometer. Do not proceed until the temperature has stabilized. Do not allow the fluid to exceed 140°F (60°C) unless your fluid manufacturer recommends higher temperatures.

15.Spray fluid into a waste pail for about 10 seconds to bring heated material to the gun.

16.Hook the drain hose (13) on the fluid supply pail.

IV. Setting Fiuid and Air Pressure

1.

With the system primed, the gun regulator (6b)

 

closed, and the pump air regulator (6a) set as

.

instructed in Step 10 on page 8, adjust the fluid

 

pressure regulator (44) to the fluid manufacturer’s

 

specifications, if available. Otherwise, follow Step

 

2 to determine the fluid pressure setting.

2.

To determine the fluid pressure setting, hold the

 

gun parallel to the floor. (Be sure to catch the fluid

 

in a container.) With the gun air pressure turned

OFF, trigger the gun. Adjust the fluid pressure reg- ulator (4) until the straight fluid stream is within the range indicated for the viscosity of your fluid before it drops off. See Fig. 8. Make note of the pressure on the fluid gauge it is your optimal fluid pressure setting.

Fluid Viscosity

Fluid Droop A

Measured with #2 Zahn cup

 

Light (18-25 seconds) 8-10” (200-250 mm)

Medium (25-40 seconds) 6-8” (150-200 mm)

Heavy (40-60 seconds) 4-6” (100-l 50 mm)

03998

3 . Be sure the gun’s fan pattern adjusting valve (E) has been turned OUT fully clockwise and then turned IN two full turns. See Fig. 9.

4. Release the trigger. Install the air cap.

5 . Partially trigger the gun so only air is emitted. Set the gun air regulator (6b) pressure to 60 psi (4.2 bar)70

psi (4.9 bar).

.

6 . Spray a stationary test pattern on scrap paper. Hold the gun 10 to 12 in. (250 to 300 mm) from the paper, and spray for 2 or 3 seconds. If the spray pattern is poorly atomized, you may need to adjust the air or fluid pressure.

If the spray pattern atomization is not fine enough, increase the gun air pressure. If the spray pattern atomization is too fine, decrease the gun air pres- sure. If the atomization is still not good enough, try lowering the fluid pressure in increments of 2 or 3 psi to achieve the desired finish quality.

NOTE: For the most efficient paint usage, use the lowest air pressure needed to obtain a good finish. Higher air pressures create more overspray and uses more fluid.

7 . Adjust the fan pattern adjusting valve (E) to fine tune the spray pattern. Turn counterclockwise to widen spray pattern. Turn clockwise to narrow

spray pattern. See Fig. 9.

308-448 9

Page 10
Image 10
Haier 237410 manual IV. Setting Fiuid and Air Pressure, Measured with #2 Zahn cup