Operation example 2

Setting the areas for normal and alarm recordings individually.

Operation

Performs alarm recording at the specified recording rate.

Performs normal recording at the specified recording rate and sets repeat recording for normal area.

Records the data of normal and alarm recordings to the different areas in order to store the alarm recording data for long term.

Settings

<Alarm area settings> ( see pages 74 and 75)

System Menu

5 Memory

3 Data Management Setting for Main Memory

step 1

4 Change Partition Setting

step1. Set the normal and alarm recording areas.

<Repeat recording settings> ( see pages 74 and 75)

System Menu

5 Memory

step 2

3 Data Management Setting for Main Memory

step2. Set the repeat recording setting of normal recording area to “Repeat On” and alarm recording area to “Repeat Off.”

<Recording settings> ( see pages 46 to 48)

Setup Menu

1 Recording

1 Set Recording Pattern A

step 3

1Camera Check

2Normal Recording Menu

step 4

DRecording Setting A-Normal (Easy)

step 5

3Alarm Recording Menu

step 6

DRecording Setting A-Alarm (Easy)

step 7

5Alarm Trigger In/Out

step3. Execute camera check to detect the cameras with video signal input automatically.

step4. Use “Easy” to set the desired recording rate for normal recording.

step5. Set the alarm mode to “Alarm CH.”

step6. Use “Easy” to set the desired recording rate for alarm recording.

step7. Set the alarm recording trigger to “External.”

A measuring for setting the partition capacity

Refer to the example below when calculating the alarm recording area capacity.

(Example:)

Alarm recording time is set to 15 seconds.

The number of alarm recordings is 80 times per day. Alarm recording data is stored for 3 months.

Picture grade for alarm recording is set to “Super” (40 kbytes), recording rate is set to “25 pps.”

1)When the partition function is set to off (alarm area is set to 0%), the estimated recordable time is 68 hours when operating with one camera at the recording rate of “25 pps” and the picture grade of “Fine.” (Set the normal recording rate using “Manual,” and check the estimated recording time in the overview screen.)

2)The alarm recording time per day is:

15 seconds multiplied by 80 times makes 1200 seconds

(20 minutes).

3)The alarm recording time per month is:

20 minutes multiplied by 30 days makes 600 minutes

(10 hours).

4)As the estimated recordable time is 68 hours; Divide 10 hours by 68 hours makes 14.7 %.

5)Alarm area capacity is 20 % with some spare capacity.

This example shows the reference when the alarm mode is set to “Alarm CH.” Adjust the partition capacity after the actual operation.

ENGLISH

•••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••• Operation examples

83

Page 83
Image 83
Mitsubishi Electronics DX-TL5000E Settings Alarm area settings see pages 74, Repeat recording settings see pages 74

DX-TL5000E specifications

The Mitsubishi Electronics DX-TL5000E is a cutting-edge digital video recorder (DVR) designed for versatile security surveillance applications. Renowned for its reliability and advanced features, this unit caters to a wide range of industries, including retail, banking, and transportation. The DX-TL5000E stands out in the market for its impressive performance and user-friendly functionality.

One of the main features of the DX-TL5000E is its ability to support up to 64 camera inputs. This scalability allows users to monitor large premises effectively and ensures comprehensive coverage for critical areas. The DVR supports various camera types, including analog and IP cameras, making it adaptable to existing surveillance systems.

The unit is equipped with advanced recording capabilities, including real-time recording at up to 30 frames per second (fps) per channel. This ensures high-quality video capture, which is essential for accurately identifying individuals and events during playback. The DX-TL5000E also offers customizable recording modes, allowing users to set specific schedules or trigger recording based on motion detection.

Another notable technology in the DX-TL5000E is its digital compression techniques. Utilizing H.264 compression, the DVR optimizes storage efficiency while maintaining superior video quality. This means users can store extensive video footage without requiring excessive amounts of hard drive space. Additionally, the system supports RAID configuration, enhancing data redundancy and security.

The user interface of the DX-TL5000E is designed for quick navigation and ease of use. Users can access live feeds, playback footage, and manage settings through a straightforward on-screen menu. Furthermore, the DVR includes remote access capabilities, allowing users to view their surveillance feeds via mobile devices or computers, which adds flexibility and convenience.

With robust network features, the DX-TL5000E supports TCP/IP protocols, making it suitable for integration into modern network infrastructures. This enables remote monitoring, alarm notifications, and seamless connectivity with other security devices.

In conclusion, the Mitsubishi Electronics DX-TL5000E is an exceptional digital video recorder that combines advanced recording capabilities, high-quality video compression, and versatile connectivity options. Its extensive features and user-friendly design make it an ideal choice for businesses looking to enhance their security surveillance systems. Whether for large facilities or complex environments, the DX-TL5000E provides a reliable solution for comprehensive safety and security management.