52
••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••

Overlapped timer settings

When the recording period of 2 or more programs are

overlapped, the unit gives priority to the higher-numbered

program.

Example 1

Program 1 is set for 14:00 to 17:00 with the normal recording
rate of 5 pps.
Program 2 is set for 15:00 to 16:00 with the normal recording
rate of 1 pps.
Under this condition, the unit will give priority to Program 2 for
the duration of the overlapping period, from 15:00 to 16:00.
The unit will operate as shown in the chart below.
14:00 15:00 16:00 17:00
14:00 15:00 16:00 17:00
In Program 1, recording rate is set to
5 pps, time period is set from 14:00 to 17:00.
1 pps
In Program 2, recording rate is set to
1 pps, time period is set from 15:00 to 16:00.
Actual recorded contents 5 pps 5 pps
Program 2
5 pps
1 pps
Program 1 Program 1

Recording is not performed if there is an error in the setting. To prevent such errors for timer recording, this unit notifies

errors using methods shown below. If there is an error in the setting, take the necessary procedures shown below.

Example 2

Program 1 is set for 14:00 to 17:00 with the normal recording
rate of 5 pps.
Program 2 is set for 15:00 to 16:00 with the SKIP setting.
Again, the unit gives priority to Program 2 for the duration of
the overlapped period. As shown in the illustration below, the
unit activates the Skip setting from 15:00 to 16:00.
5 pps 5 pps
NO
RECORDING!
14:00 15:00 16:00 17:00
14:00 15:00 16:00 17:00
SKIP
In Program 2, SKIP is set for
15:00 to 16:00.
5 pps
Actual recorded contents
Program 2
Program 1 Program 1
In Program 1, recording rate is set to
5 pps, time period is set from 14:00 to 17:00.
Timer (continued) Setup Menu
Unit status Description of error Countermeasure Page
55
51, 52
51, 52
74, 75
TIMER indicator flashes
and the series of short
beeps (beep-beep-beep)
sounds.
Timer recording does not
perform even when the
programmed time is
reached.
1) The date/time is not set.
2) Timer program setting has not
been set to operate.
3) Program is currently being set.
1) Repeat recording settings for
"Normal Recording Area," "Alarm
Recording Area," and "LPA
Recording Area" (System Menu
Memory Data Management
Setting for Main Memory) are set
to "Repeat Off," and there is no
HDD space left.
1) Set the date/time.
2) Set the correct program.
3) Deter mine the settings.
Clear the warning display.
Set the repeat recording settings for "Normal
Recording Area," "Alarm Recording Area,"
and "LPA Recording Area" (System Menu
Memory Data Management Setting for Main
Memory) to "Repeat On."