INSTALLATION MANUAL FOR OUTDOOR UNIT
(5) Purging method ( the refrigerant is R407C)
To use vacuum pump
1
Detach the service port's cap of
2
Open the handle at low in gaugemanifold, operate
vacuum pump. If the
3
Vacuumize for over 15min. And check the level gauge which should read
pressure side. After the completion of vacuumizing,
close the handle 'Lo' in gaugemanifold and stop the3 Close operation of the vacuum pump.
Check the condition of the scale and hold it for
Liquid pipe
6.35mm(1/4'')
Gas pipe
12.7mm(1/2'')
Gaugemanifold
Vacuum pump
4
Open the valve rod for the
After 6 seconds later, close the
5 | In case of gas leakage, tighten | |
| ||
No gas leakage? | parts of pipe connection. If | |
leakage stops, then proceed 6 | ||
| ||
| steps. | |
6 |
|
Detach the charge hose from the service port, open
7
To prevent the gas leakage, turn the service port's cap, the valve rod'd cap for
8
After attaching the each caps, check the gas leakage around the caps.
CAUTION:
If the refrigerant of the air conditioner leaks, it is necessary to make all the refrigerant out, then charge the liquid refrigerant into air conditioner according to the amount marked on the name plate.
3-way valve 3-way valve
90 | 90 | Service port | |
4 90 for 6 sec. | |||
|
|
If it does not stop gas leakage, discharge whole refrigerants from the serice port. After flaring work again and vacuumize, fill up prescribed refrigerant from the gas cylinder.
6
6
|
7 Valve rod cap
7 Valve rod cap 7 Service port cap
14