Is the power source switch adjust cut in?
ON
OFF
Power supply switch is not ON.
Is the thermostat adjust as required?
Isn't the swing louver horizontal?
(At HEATING mode) If swing louver is horizontal, the blow wind does not reach floor.
The wind does not blow during heating operation
Isn't it warming up?
page 9

MALFUNCTION

please check the following things about your air conditioner before making a servie call.

Unit fails to start

Is city supply power in normal?

Power stoppage?

Isn't the signal receiving section exposed to the direct sunlight or strong illumination?

Isn't the earth leakage breaker in action?

It is dangerous. Turn off the power supply switch immediately and contact the sales dealer.

Cooling or heating is not sufficient

Isn't the air filter dirty?

Isn't any doors or windows

 

left open?

 

 

Doesn't any obstacle exist at the air inlet or outlet?

Cooling is not sufficient

Isn't sun-shine invading

Isn't any unexpected

direct?

heating load generated?

 

 

Isn't the room much crowded?

When the air conditioner does not operate properly after you have checked the above mentioned items or when the following phenomenon is observed, stop the operation of the air conditioner and contact your sales dealer.

The fuse or breaker often shuts down.

Water drops off during cooling operation.

There is a irregularity in operation or abnormal sound is audible.

When the CHECK lamp flickers, an irregularity has occurred in the air conditioner.

Flickering

F1

F2

F4

F5

F7

E1

E2

E3

 

 

 

 

 

 

 

 

 

Content

The trouble

The trouble

The trouble of

The trouble of

The trouble of

The trouble

 

The trouble of

the wiring

 

 

the indoor

of defect

of the room

of the pipe

the overload

the cooling ice

controller

of the

No load

and outdoor

 

temp.sensor

temp. sensor

heating

over

and outdoor

module

 

comumication

 

 

 

 

 

comumication

 

 

 

 

 

 

 

 

 

 

 

 

Flickering

E4

E5

E6

E7

E8

E0

EA

EC

EE

 

 

 

 

 

 

 

 

 

 

Content

The trouble

The trouble of

The trouble of

The trouble of

singlechip

The trouble

voltage of

The trouble

E2PROM

the outdoor

of defect

of the comp.

the overload

the outdoor

bad

of the water

power supply

of the

bad

room temp.

pipe temp.

 

too hot

current

 

pump

too high

overload

 

 

 

 

sensor

sensor

 

 

 

cooling

 

 

 

 

 

 

 

 

 

 

 

Note:

This unit has a function of automatic restart system after recovering power stoppage. Please contact the sales dealer if it is not required.

7

Page 8
Image 8
Haier AD142AMBIA Malfunction, Unit fails to start, Cooling or heating is not sufficient, Cooling is not sufficient