INSTALLATION MANUAL FOR INDOOR UNIT

(4)Preparation for suspending the unit

(a)Figure of installation dimension: (unit: mm)

1024

452

100

55

225

123

 

225

 

 

 

22

Standard pressure 0 Pa , Middle pressure 50Pa

990

When install the duct hidden type indoor unit, the return air box must be designed and installed, as Figure3, Figure4.

The distance between the air outlet of duct and the air outlet of air conditioner should be no more than 1m.

The distance between the air outlet of duct and the air outlet of air conditioner should be no more than 1.0m(use white motor plug);

The distance between the air outlet of duct and the air outlet of air conditioner should be no more than 5.0m(use red motor plug).

Building roof of installation

(Figure 3)

1.0m (use white motor plug) 5.0m(use red motor plug)

Ceiling

A

Unit

Return air box

Air supply

Return air

Air outlet grille

Air supply

There should be no obstacles within 1m

(Figure 4)

Unit

Return air box

Return air

17

Page 18
Image 18