SAFETY PRECAUTIONS

The machine is adaptive in following situation

1. Applicable ambient temperature range:

 

 

 

Rated

Maximum

Minimum

 

Indoor

DB C

27

32

18

Cooling

WB C

19

23

14

 

outdoor

DB C

35

43

-5

 

 

WB C

24

26

--

 

 

Heating

Indoor

DB C

20

27

15

 

WB C

14.5

--

--

 

 

 

outdoor

DB C

7

24

-7

 

WB C

6

18

--

 

 

2.If the supply cord is damaged, it must be replaced by the manufacturer or its service agent or a similar qualified person.

3.If the fuse on PC board is broken please change it with the type of T3.15A /250VAC.

4.The wiring method should be in line with the local wiring standard.

5.Use copper wire only. The connecting cable should be H05RN-F 4G 0.75mm2. The power cable should be H07RN-F 3G 2.5mm2. All the cables shall have got the European allthentication certificate.

6.The power supply connects from the outdoor side.

7.The breaker of the air conditioner should be all-pole switch; and the distance between its two contacts should be no less 3mm.

8.The indoor unit installation height is at least 2.5m.

Note:

Part of the power supply of the air conditioner are not prepared because of the requirement of the dealer, the power supply should be provided for oneself.