Haier AU142AFBIA Heat Pump model/Cooling Only model, Accessories, Installation of outdoor unit

Models: AU142AFBIA AD142AMBIA

1 24
Download 24 pages 25.16 Kb
Page 13
Image 13
<Heat Pump model/Cooling Only model >

1. Accessories INSTALLATION MANUAL FOR OUTDOOR UNIT

<Heat Pump model/Cooling Only model >

2. Selection of the place of installation(1) Open space requirement around the unit WARNING

BE SURE TO READ THESE INSTRUCTIONS CAREFULLY BEFORE BEGINNING INSTALLATION. FAILURE TO FOLLOW THESE INSTRUCTIONS COULD CAUSE SERIOUS INJURY OR DEATH, EQUIPMENT MALFUNCTION AND/OR PROPERTY DAMAGE. BE SURE TO READ INSTALLATION MANUAL FOR INDOOR UNIT WITH THIS MANUAL.

1. Accessories

Edging

"Edging" for protection of electric wires from an opening edge.

2. Selection of the place of installation

Select the place of installation satisfying the following conditions and, at the same time, obtain a consent from the client or user.

(2) Installation where the area with strong winds. Place where air circulates.

3. Installation of outdoor unit Place free from heat radiation from other heat sources.

(1) Installation Place where drain water may be discharged.

Manual background Place where noise and hot air may not disturb the neighborhood.

Manual background Place where there is not heavy snowfall in the winter time.

Manual background Place where obstacles do not exist near the air inlet and air outlet .

Manual background Place where the air outlet may not be exposed to a strong wind.

Manual background Place surrounded at four sides are not suitable for installation. A 1m or more of overhead space is needed for the unit.

Manual background Mount guide-louvers to place where short-circuit is a possibility.

Manual background When installing several units, secure sufficient suction space to avoid short circuiting.

(1) Open space requirement around the unit

Unit: mm

Manual backgroundManual background L2

Air inlet

Manual backgroundAir inlet Manual background L3

Manual background 500

(Servicing

space)

Air outlet

Manual backgroundL1

Distance

Case

I

II

III

 

L1

 

open

open

500

 

 

 

 

 

L2

 

300

0

open

 

 

 

 

 

L3

 

150

300

150

 

 

 

 

 

(2) Installation where the area with strong winds.

Install the unit so that the air outlet section of the unit must NOT be faced toward wind direction.

3. Installation of outdoor unit

NO

(1) Installation

Fix the unit in a proper way according to the condition of a place where it is installed by referring to the following .

(a) Concrete foundation

Unit

Anchor bolt

Concrete foundation

To fix by bolts

Note (1) Give enough room for the concrete foundation to fix by anchor bolts.

Foundation anchor

Unit

Manual background Concrete foundation

Anchor bolt

Note (1) Place the concrete foundation deep enough.

Manual background Install the unit so that the angle of inclination must be less than 3 degrees. 12