![Indoor Unit](/images/new-backgrounds/32604/3260435x1.webp)
Installation Procedure
Indoor Unit
Selection of indoor unit installation place
Place where it is easy to route drainage pipe and outdoor piping.
Place away from heat source and with less direct sunlight.
Place where cool and warm air could be delivered evenly to every corner of the room.
Place near power supply socket. Leave enough space around the unit (refer to installation drawings).
Installation of indoor unit
1.Position of the wall hole
Wall hole should be decided according to installtion place and piping direction. (refer to installation drawings)
2.Making a wall hole
Drill a hole of 70mm dia. with a little slope towards outside. Install piping hole cover and seal it with putty after installation.
3.Fixing of indoor unit
With the unit set up vertically, fix the fitting metal to the unit with screws, then fix the fitting metal to the wall with cement nail and washer, as shown right:
Moreover, if wanting to fix the unit more firmly, you should fix the bottom panel to the ground with concrete bolts, as shown right:
INDOOR SIDE | OUTDOOR SIDE |
| ||
wall hole |
| wall thickness |
| |
|
|
| ||
70mm |
|
|
|
|
( Cross section of wall hole ) |
| |||
Cement nail |
|
|
|
|
Fitting metal |
| 2- 10 hole | ||
|
| 330 | ||
|
|
|
| |
Screw |
|
|
|
|
4- 14 hole 30 depth | 260 |
| ||
130 |
| |||
|
|
| (79) | |
|
|
| 79 | |
Fitting hole |
|
| 202 | (202) |
|
|
|
| |
Bottom Panel |
|
|
|
16