ENGLISH

PAGE 8 INSTALLATION REQUIREMENTS

ELECTRICAL REQUIREMENTS cont.
POWER SUPPLY CORD (See Fig.1)
Wiring Requirements
For model ESA415M
• 115-volt (103.5 minimum to 126.5 maximum)
• 15-amp time-delay grounded fuse or circuit breaker
• Use on single outlet circuit only.
For model ESA418M
• 230/208 volt (187 min. to 253 max.)
• 15-amp time-delay fuse or circuit breaker
• Use on single outlet circuit only.
For model ESA424K
• 230/208 volt (187 minimum to 253 maximum)
• 20-amp time-delay grounded fuse or circuit breaker
• Use on single outlet circuit only.
RECOMMENDED GROUNDING METHOD (See Fig.1)
This air conditioner must be grounded. This air conditioner is equipped with a power supply
cord that has a 3 prong grounding plug. The power supply cord must be plugged into a mating,
grounded 3 prong outlet, and grounded in accordance with all local codes and ordinances. If a
mating outlet is not available, it is the customer’s responsibility to contact a qualified electrician
and ensure that a properly grounded 3 prong outlet is installed.
POWER SUPPLY CORD (See Fig.2)

NOTE: Your air conditioner's plug may differ slightly in appearance

from the one shown.

A. Reset button

B. Test button

This room air conditioner is equipped with an a leakage current detection interrupter (LCDI)

power supply cord required by UL. This power supply cord contains a current detection device.

If the power supply cord is crushed, this device will detect current leakage and power will be

disconnected from the air conditioner. If this power supply cord is damaged, it cannot be

repaired and must be replaced with a cord from the product manufacturer. If the power supply

cord is damaged call Haier Customer Service: 1-877-337-3639.

RESET
TEST
A
B
Fig. 2
Fig. 1
ESA415M
ESA418M
ESA424K
ESA415 ESA418 ESA424
115V
15 Amp
230V
15 Amp
230V
20 Amp
ESA415 ESA418 ESA424
115V
15 Amp 230V
15 Amp
230V
20 Amp
ESA415 ESA418 ESA424
115V
15 Amp
230V
15 Amp 230V
20 Amp