840129900 ENv02.qxd 11/1/04 11:00 AM Page 3
wWARNING
Germicidal Light Radiation Hazard
•Never operate with damaged, broken or missing outlet grille louvers or without the outlet grille.
•Never operate with damaged, broken or cracked housing.
•Always unplug unit before cleaning, servicing or replacing the UV bulb.
•Never look directly at UV bulb or place face directly on outlet grille.
•Use only Hamilton Beach replacement UV bulb: Part No. 04810.
•Read all instructions before using.
Failure to follow these instructions can result in direct exposure to germicidal light, which can cause temporary or chronic damage to your eyesight, or even blindness.
About Your Air Purifier
The air purifier functions as an air cleaner by helping to disinfect airborne bacteria and removing particulates from the air.
The air is cleaned in three stages:
1.A fan draws air through the intake grille on the front of the air purifier. Then it passes through the carbon
2.The white HEPA filter then removes particles as small as 0.3 microns from the air at 99.97% effectiveness.
3.The clean air is then exposed to
To Order Replacement Parts
Replacement parts may be available where the air purifier was purchased or can be obtained directly from Hamilton Beach.
Purifier | Control | Room Size* | Carbon | HEPA | UV Bulb | Starter Type |
Model | Type | (sq. ft.) | Filter |
| ||
|
|
|
|
|
|
|
04160 | Manual | 200 ft2 | 04922 | 04912 | 04810 | 904004100 |
04161 | AirSmart™ | 200 ft2 | 04922 | 04912 | 04810 | 904004100 |
04162 | Manual | 350 ft2 | 04923 | 04913 | 04810 | 904004100 |
|
|
|
|
|
|
|
04163 | AirSmart™ | 350 ft2 | 04923 | 04913 | 04810 | 904004100 |
*Each air purifier is designed to filter the room five times per hour at high speed. Factors such as room shape and ceiling height can affect this rate. It is normal that the air flow will be reduced as the filters become clogged. See “Checking the Filters” on page 10 for more information.