ters to be replaced and xx2 defines replacement characters, continuing through zz1 and zz2.

E5 Terminates character replacement. Syntax = E5.

FE Compare character in current cursor position to the character “xx.” If char- acters are equal, increment cursor. If characters are not equal, no format match. Syntax = FExx (xx stands for the hex value for an ASCII code, see Decimal to Hex to ASCII Conversion chart, page 4-6.)

EC Check to make sure there is an ASCII number at the current cursor position. If character is not numeric, format is aborted. Syntax = EC.

ED Check to make sure there is a non-numeric ASCII character at the current cursor position. If character is numeric, format is aborted. Syntax = ED.

Data Format Editor

Enter Data Format

Default Data Format

Clear One Data Format

Clear All Data Formats

Save

Discard

5 - 4

3800/3900 User’s Guide

Page 62
Image 62
Hand Held Products 3900, 3800 manual Data Format Editor