User’s Guide
Disclaimer
FCC Class B Compliance Statement
Statement of Agency Compliance
Canadian Notice
TÜV Statement
LED Safety Statement
UL and cUL Statement
TIC Statement
Table of Contents
Output
Data Formatting
Code 93 Message Length
Check Digit Addenda Addenda Required Addenda Separator
Cloning
Maintenance
Viii
Typical Applications for
Getting Started
About This Manual
Unpacking the Scanner
Or an
Scanner Identification
Scanner Bottom View
Connecting the Scanner When Powered by Host Keyboard Wedge
For
Plug and Play
Mounting Information
Specular Zone
Option Setting
IBM 4683 Ports 5B, 9B, and 17 Interface
Symbology Suffix
USB Interface
3800/3900 User’s Guide
Ocia Interface
Symbology Prefix
NCR Ocia Short Format 8 Bit Interface
Nixdorf Ocia Interface
Symbology
NCR Ocia Long Format 9 Bit Interface
Serial Wedge
3800/3900 User’s Guide
3800/3900 User’s Guide
Terminal Interfaces
Keyboard Wedge Connection
Terminal ID
Supported Terminals
Terminal Models Terminal ID
Supported Terminals
Keyboard Style
Keyboard Country
Country Code Scan
Keyboard Modifiers
3800/3900 User’s Guide
Serial Port Connection
Baud Rate
RS-232 Word Length Data Bits, Stop Bits, and Parity
RS-232 Word Length Data Bits, Stop Bits, and Parity
RS-232 Handshaking
Wand Emulation Connection
Wand Emulation Transmission Rate
Wand Emulation Polarity
Wand Emulation Idle
Delay Between Blocks
Data Block Size
Overall Checksum
Output
Beeper Volume
Scan Rate
Scan Voting
Beeper Tone
Reduce Quiet Zone
Reread Delay
Good Read Delay
Trigger Mode
Serial Trigger Time Out
3800/3900 User’s Guide
Prefix/Suffix Overview
Scan the Add Prefix or Add Suffix symbol
Data Editing
Points to Keep In Mind
To Clear One or All Prefixes or Suffixes
Scan the Clear One Prefix or Clear One Suffix symbol
Scan Add Suffix
To Add a Carriage Return Suffix to all Symbologies
Prefix Selections
Suffix Selections
Hex Symbology Code
Symbology Chart
Symbology Code
Hex
Ascii Conversion Chart Code
Dec Hex Char
Intercharacter Delay
Intercharacter, Interfunction, and Intermessage Delays
Function Code Transmit
User Specified Intercharacter Delay
Interfunction Delay
Intermessage Delay
3800/3900 User’s Guide
Data Format Editor Introduction
Scan the Enter Data Format symbol Primary/Alternate Format
Data Formatting
To Add a Data Format
Data Format Editor Commands
Other Programming Selections
Move Commands
Data Format Editor
Data Formatter
Alternate Data Formats
3800/3900 User’s Guide
Secondary Code 39 Wand Emulation
Secondary Interface
Secondary RS-232 Connection
Non Decoded Output Laser Emulation Transmission Rate
Secondary Non Decoded Output Laser Emulation
Non Decoded Output Laser Emulation Polarity
Non Decoded Laser Emulation Idle
Secondary Trigger Mode
Disabling the Secondary Interface
3800/3900 User’s Guide
All Symbologies
Symbologies
Introduction
Message Length Description
Codabar
Start/Stop Characters
Check Character
Codabar Message Length
Concatenation
Codabar
Code
Code 39 Message Length
Code 39 Append
Base
Full Ascii
Interleaved 2
Check Digit
Interleaved 2 of 5 Message Length
Strict Decoding
Code 93 Message Length
Iata Code 2
Code 2
Code 2 of 5 Message Length
Matrix 2
Iata Code 2 of 5 Message Length
Matrix 2 of 5 Message Length
Check Digits Required
Code 11 Message Length
GS Substitution
Telepen
Code 128 Message Length
Telepen Output
Telepen Message Length
Number System
Addenda
UPC a
Addenda Required
Addenda Separator
UPC Strict Decoding
UPC E0 and UPC E1
UPC E Expand
UPC E
Addenda
Addenda Separator
EAN/JAN
EAN/JAN
Isbn Enable
Default All EAN/JAN 8 Settings
Addenda
Addenda Separator
MSI
MSI Message Length
Plessey
Plessey Message Length
RSS-14
RSS Limited
RSS Expanded
RSS Expanded Message Length
China Post Code
China Post Message Length
Off Minimum Message Length Maximum Message Length
Scan Diagnostics
Show GLI Blocks
3800/3900 User’s Guide
Minimum Message Length Maximum Message Length
Enable UPC/EAN Version
Eanucc Composite Symbology
Eanucc Composite
Eanucc Composite Code Message Length
3800/3900 User’s Guide
Procedure
Cloning
3800/3900 User’s Guide
Visual Menu
Temporary Visual Menu Configuration
Installing Visual Menu from the Web
Visual Menu Introduction
Upgrading USB Firmware
Keyboard Function Relationships
Interface Keys
Function Code HEX/ASCII Value Full Ascii Ctrl +
Country Codes
PS/2 Compatibles IBM XTs IBM, DDC, Memorex Interface Keys
Supported Interface Keys
IBM AT/XT
Compatibles Telex, Harris
Memorex Telex
SYN PF1 ETB PF2 Can PF3 PF4 SUB PF5 ESC PF6 PF7 PF8 PF9
Esprit 200 Interface Keys
Ansi Ascii
Supported Interface Keys Apple Mac/iMac
Show Software Revision
To Add a Test Code I.D. Prefix to All Symbologies
Utilities
Show Data Format
Specular Effect Reduction
Menu Command Syntax
Serial Programming Commands
Conventions
Concatenation of Multiple Commands
Query Commands
Responses
Examples of Query Commands
Trigger Commands
Resetting the Factory Settings
Menu Commands
Setting Serial Selection Command
WNDPAT0
Output Selections
Prefix/Suffix Selections
Data Formatter Selections
Symbologies
Selections
CBRSSX0
I25STR0
Teldft
UPAARQ0 UPAARQ1
E13ARQ0
Plsdft
Mpddft
Product Specifications
Product Specifications
Parameter Specification
Product Specifications
Cable Pinouts
Standard
Laser
Compatible
Pinouts
Standard Cable
WandEmulation
Pinouts Primary Interface Cables
Serial Output Standard Cable
Standard Cable Pinouts
USB
3800/3900 User’s Guide
Cleaning the Scanner’s Window
Maintenance
Maintenance
Inspecting Cords and Connectors
Replacing the Interface Cable
Troubleshooting
To Replace the Interface Cable
Is the scanner having trouble reading your symbols?
3800/3900 User’s Guide
Product Service and Repair
Customer Support
Asia Pacific
Online Product Service and Repair Assistance
Technical Assistance
Japan
Online Technical Assistance
Limited Warranty
3800/3900 User’s Guide
3800/3900 User’s Guide
Page
Page
Page
Sample Symbols
Matrix 2
Programming Chart
Save Discard
Hand Held Products, Inc