Oakleaf Woodburning Stove

B. Clearances To Combustibles

CLEARANCE TO COMBUSTIBLES: Vertical Venting Configuration

Location

AUnit to Side Wall

B Unit to Back Wall

C Vent Pipe to Side Wall

D*

Vent Pipe to Back Wall

17" / 432 mm 14" / 356 mm 26.75" / 679 mm *17.5" / 444 mm

Pipe clearance may be reduced using double wall or insulated connector pipe, provided that you adhere to the specified clearances from the stove itself. Follow pipe manufacturer's guidelines.

C

A

D*

B

*NFPA 211 specifies 18" clearance to single wall connector pipe. This lower clearance is based on actual safety test conditions.

For clearance reduction methods, refer to NFPA 211 or Local Codes

CLEARANCE TO COMBUSTIBLES: Vertical Vent, Horizontal Exit

 

Location

 

A

Unit to Side Wall

16" / 407 mm

B

Unit to Back Wall

13" / 330 mm

C

Vent Pipe to Side Wall

25.25" / 641 mm

D*

Vent Pipe to Back Wall

*17" / 432 mm

E*

Vent Pipe to Ceiling

*16" / 407 mm

F

Minimum Vertical

0" / 0 mm

Pipe clearance may be reduced using double wall or insulated connector pipe, provided that you adhere to the specified clearances from the stove itself. Follow pipe manufacturer's guidelines.

*NFPA 211 specifies 18" clearance to single wall connector pipe. This lower clearance is based on actual safety test conditions.

 

E

F

C

 

A

C

A

E

D

B

10 Dry Seasoned Wood Only!

3-90-798

Save These Instructions

Page 10
Image 10
Harman Stove Company 1-90-797000 manual Clearances To Combustibles, 17 / 432 mm 14 / 356 mm 26.75 / 679 mm *17.5 / 444 mm