Oakleaf Woodburning Stove

Oakleaf to Flue Fireplace Conversion (Minimum NFPA 211 Liner Connection)

Flue Liner with Re- quired Air Space

Stainless Steel Chimney Connector Must Extend to Flue Liner

Minimum 8" Masonry

Thickness in Front of

Smoke Chamber

Use Damper Adapter or Seal with Non-Combustible Material

Damper Plate is Removed or Fastened in Open Posi- tion

Listed Fireplace Trim Protection for Re- duced Clearance

Airtight insulated Clean-Out

Floor Protection*

Combustible Floor

*Floor Protection in Accordance with Solid Fuel Appliance Listing

NOTICE: When using rear flue configuration, a new upper rear heat shield, #1-00-797066 must be installed in place of the existing shield.

The Chimney Connector Shall Not Pass Through an Attic or Roof Space, Closet or Similar Concealed Space, a Floor or Ceiling.

18 Dry Seasoned Wood Only!

3-90-798

Save These Instructions