Harman Stove Company 1-90-797000 manual Flue Liner with Required Air Space

Models: 1-90-797000

1 40
Download 40 pages 46.92 Kb
Page 20
Image 20
Flue Liner with Required Air Space

Oakleaf Woodburning Stove

Chimney Breach Fireplace Conversion with Combustible Wall

Minimum Clearance from Chimney Connector to Un- protected Ceiling

Flue Liner with Required Air Space

Listed or Approved Thimble Assembly

1" Clearance for Complex- ity Exterior Chimney

or

2" Clearance for Interior Chimney and 2" Clear- ance for NFPA 211-Type Approved Thimbles

16"**

Combustible

Wall

Sheetrock

Airtight insulated Clean-out

Mantel & Trim

Protection

Damper Closed and

Sealed with Non-

Combustible

Material.

Floor Protection*

Combustible Floor

*Floor Protection in Accordance with Solid Fuel Appliance Listing ** Check with your local building codes for clearance.

The Chimney Connector Shall Not Pass Through an Attic or Roof Space, Closet or Similar Concealed Space, a Floor or Ceiling.

20 Dry Seasoned Wood Only!

3-90-798

Save These Instructions