11INSTALLATION
Only For Qualified Installers
Maximum of four 450 elbows allowed.
Subtract three feet of total horizontal pipe
length for each of the 3rd and 4th 450 elbows
used.
Maximum of two 900 elbows allowed.
Subtract five feet of total horizontal pipe
length for second elbow.
Venting with 6 5/8” x 4” Pipe
A combination of one 900 elbow and two 450
elbows is allowed.
Subtract three feet of total horizontal pipe
length for each 450 elbow used.
This appliance must not be
connected to a chimney flue
serving a separate solid fuel
burning appliance.
6 5/8 to 8” Increaser
8”
CONQUEST

Rear Vent

A snorkel termination is
recommended when no
vertical pipe is used.
Vent termination must remain within the
shaded area regardless of configuration.