Requirements for Terminating the Venting

I. The clearance to service regulator vent outlet

WARNING: Venting terminals must not be re-

must be a minimum of 6 feet (1.8 m).1

 

cessed into a wall or siding.

 

J. The clearance to a non-mechanical air sup-

In addition, the following must be observed:

ply inlet to the building or the combustion air inlet

A. The clearance above grade, or a veranda,

to any other appliance must be a minimum of 12

porch, deck or balcony must be a minimum of 12"

inches (30 cm).1

 

(30 cm).1

 

K. The clearance to a mechanical air supply

B. The clearance to a window or door that may

inlet must be a minimum of 6 feet (1.8 m).1

 

be opened must be a minimum of 12" (30 cm).1

L. The clearance above a paved sidewalk or a

C. A 12" (30 cm) clearance to a permanently

paved driveway located on public property must be

closed window is recommended to prevent con-

a minimum of 7 feet (2.1 m).1,2

 

densation on the window.

 

M. The clearance under a veranda, porch, deck

D. The vertical clearance to a ventilated soffit

or balcony must be a minimum of 12 inches (30

located above the terminal within a horizontal dis-

cm).1,3

 

tance of 2 feet (60 cm) from the center-line of the

1As specified in CAN 1 B1-149 Installation

terminal must be a minimum of 18" (46 cm).

Codes (current edition). Note: Local codes or regula-

E. The clearance to an unventilated soffit must

tions may require different clearances.

 

be a minimum of 12" (30 cm).

 

2A vent shall not terminate directly above a side-

F. The clearance to an outside corner is 11" from

walk or paved driveway which is located between

center of pipe.

 

two single family dwellings and serves both dwell-

G. The clearance to an inside corner is 12" (30

ings.

 

cm).

 

3Only permitted if veranda, porch, deck, or bal-

H. A vent must not be installed within 3 feet

cony is fully open on a minimum of 2 sides beneath

(90 cm) above a meter/regulator assembly when

the floor.

 

measured from the horizontal center-line of the regu-

 

 

lator.1

 

 

 