Harman Stove Company Conquest Gas Stove manual INSTALLATION13, Damper Settings, Feet

Models: Conquest Gas Stove

1 30
Download 30 pages 22.44 Kb
Page 13
Image 13

Only For Qualified Installers

INSTALLATION13

Damper Settings

Top Vent Only

Vent damper shown in the

Maximum Draft”OPEN” position

for top vent. Note: This would be the Minimum Draft”CLOSED”

position if a rear vent was installed.

CLOSED

A vent damper is provided to allow fine tuning of the draft. Too little draft will cause flames to be too long with black tips and too much draft will cause flames to be short and blue.

To adjust the damper, burn the unit on High 10 minutes or more. Adjust the vent damper to a posi- tion in the ranges listed below that produces the most desirable flame pattern. Note: 1 is less draft and 4 is maximum draft.

Range Of Approved Damper Settings

 

Natural Gas or Propane

0 Feet (rear Vent)

Open

6

feet

1/4 to Open

12

feet

1/4 to Open

24 feet

Closed to 1/2

36 feet

Closed to 1/2

OPEN

Page 13
Image 13
Harman Stove Company Conquest Gas Stove manual INSTALLATION13, Damper Settings, Feet