Venting
12" min. | Storm collar |
| |
| Flashing |
3" min. |
|
3" min. | 3" min. |
|
PL vent manufacturer's |
fire stop s pa ce r an d |
support |
Fig. 18 |
No insulationor other combustible materials are allowed within 3" of the PL vent pipe.
(See Page 6 for corner installation clearances)
Minimumflue vent configuration
It is recommended that outside air be installed with this venting configuration.
1"2veaob roundg velle
#7 Installing through the ceiling vent
Through the ceiling vent, follow PL vent manufacturers recommendations when using wall and ceiling pass through.
Fig. 20 |
12 PC 45 Corn/Pellet Stove |
inM.
Fig. 19
DO NOT INSTALL A FLUE DAMPER IN THE EXHAUST VENTING SYSTEM OF THIS UNIT.
DO NOT CONNECT THIS UNIT TO A CHIMNEY FLUE SERVING ANOTHER APPLIANCE.
INSTALL VENT AT CLEARANCES SPECIFIED BY THE MANUFACTURER
WARNING
DO NOT INSTALL IN SLEEPING ROOM
CAUTION
THE STRUCTURAL INTEGRITY OF THE MOBILE HOME FLOOR, WALL,AND CEILING/ ROOF MUST BE MAINTAINED.
CAUTION
THE STOVE IS HOT WHILE IN OPERATION. KEEP CHILDREN, CLOTHING AND FURNITURE AWAY. CONTACT MAY CAUSE
SKIN BURNS.