Venting

12" min.

Storm collar

 

 

Flashing

3" min.

 

3" min.

3" min.

 

PL vent manufacturer's

fire stop s pa ce r an d

support

Fig. 18

No insulationor other combustible materials are allowed within 3" of the PL vent pipe.

(See Page 6 for corner installation clearances)

Minimumflue vent configuration

It is recommended that outside air be installed with this venting configuration.

1"2veaob roundg velle

#7 Installing through the ceiling vent

Through the ceiling vent, follow PL vent manufacturers recommendations when using wall and ceiling pass through.

Fig. 20

12 PC 45 Corn/Pellet Stove

inM.

Fig. 19

DO NOT INSTALL A FLUE DAMPER IN THE EXHAUST VENTING SYSTEM OF THIS UNIT.

DO NOT CONNECT THIS UNIT TO A CHIMNEY FLUE SERVING ANOTHER APPLIANCE.

INSTALL VENT AT CLEARANCES SPECIFIED BY THE MANUFACTURER

WARNING

DO NOT INSTALL IN SLEEPING ROOM

CAUTION

THE STRUCTURAL INTEGRITY OF THE MOBILE HOME FLOOR, WALL,AND CEILING/ ROOF MUST BE MAINTAINED.

CAUTION

THE STOVE IS HOT WHILE IN OPERATION. KEEP CHILDREN, CLOTHING AND FURNITURE AWAY. CONTACT MAY CAUSE

SKIN BURNS.

Page 12
Image 12