17PC 45 Corn/Pellet Stove
AUTOMATIC IGNITION ESP CONTROL
Feed adjuster
Sets the maximum
feed rate
Test
Runs all motors at full
speed for one minute
to check opera tion.
After two minutes the
stov e will g o t o
minimum burn and
the bl ower s wil l
alternate from high to
low every minute to
remind you that you
are sti ll i n "Te st
Mode".
Igniter switch
Set to appropriate
Start-Up mode.
Dist ribu tio n Blo wer
speed adjustment range.
L = low
H = high
Variable speed anywhere
betwe en L and H;
although as the sto ve
temp. goes up , so does
the L and H scale.
Temp dial
Allows you to adjust the room temperature in Room
Temp Mode using the outer scale marked in degrees
Fahrenheit. It also allows you to adjust the stove
temperature while in Stove Temp Mode using the inner
scale marked from 1 to 7.
Mode Selector
All ows you to c hoo se
between Room Temp Mode,
Stove Temp Mode, or OFF.
Also allows you to vary the
distribution blower speed by
turning the knob to the high
or low side of each mode.
Power Light
Indicates power to the
control.
Indicates power to the
feed motor.
Indicates igniter is on.
Indicates power to
combustion blower
Status Light
Will be lit in either stove
or room temp mode when
pointer is not within off
position band except
after normal shut down.
Blinks to indicate errors
listed below.
Indicates power to
distribution blower.
6 Blinks : Indicates that the control has calculated
poor or incomplete combustion occurring for more
than 50 minutes. See Troubleshooting section fo r
more details.
A six blink status may be set if the stove is allowed
to run out of pellets. To reset, turn mode selector to
"OFF" then back on to the desired mode. If the unit
was not out of pellets, see Troubleshooting section,
Page 24, for more details.
* Manual re set- Disconnect power cord for a few
seconds and reconnect. If error still occurs call your
Harman Dealer.
Status light error messages:
1 Blink: Indicates control board self diagnostic fail-
ure. This requires a manual reset*.
3 Blinks: Indicates ESP ( Exhaust Sensing Probe)
failure. This requires a manual reset*.
4 Blinks: Can occur only in Room Temp Mode and
indicates Room Sensing Probe failed or not installed.
If a Room Sensing Probe is then installed, the sta-
tus light will automatically reset.
NOTE: Unit will not start in "AUTO" with this status
error.
5 Blinks (In Igniter Aut o. Mode Only): Indicates
that the unit has failed to light within the 45 minute
start cycle. To reset - Turn Mode Selector to "OFF",
then turn to either mode again.
Dealer Diagnostic Port
For dealer maintenance use
only. Requires special DDM
monitor supplied to Harman
Dealers exclusively.