Installation

Installation

Installing

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Place the stove on a non-combustible floor

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

protector that extends a minimum of 6 inches to

 

 

 

 

 

 

 

 

 

 

 

 

6.25"

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

the front (152mm), 6 inches to the sides (152mm)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3"/ 76mm

 

 

 

 

 

 

 

 

 

 

 

and 6"(152mm) to the rear, which is flush with the

 

 

 

 

 

 

 

 

 

 

 

 

406mm

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

rear of the hopper. Front and side floor protection

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

measurements are made from the firebox or window

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

opening. Floor protection must also be positioned

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

under horizontal flue pipe, extending 2" (51mm)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

12"/ 305mm

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

beyond each side of the pipe.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

6.25"

 

 

NOTE for Canadian installation only: Per

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

406mm

 

 

ULC-S627-00, If installed on a combustible floor,

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

the need to provide a noncombustible floor protector

Fig. 3

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

covering the area beneath the space heater and

 

 

 

 

 

 

 

 

Fig. 2

 

 

 

 

 

 

 

 

 

 

 

extending at least 17.72" (450mm) on the firing side

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

and at least 7.87" (200mm) on the other sides.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

The minimum floor protector material is 20 gauge sheet

 

 

Floor Protection

 

US

 

Canada

 

 

 

 

 

 

metal. Other floor protector materials are ceramic tile, stone,

 

 

Requirements

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

brick, etc.

 

 

 

 

J

Sides

 

6"

 

 

200mm

 

 

 

 

 

 

Place the stove away from combustible walls at least as far

 

 

 

 

 

 

 

 

 

 

 

as shown in Figures 2 and 3.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

K

Front

 

6"

 

 

450mm

 

 

 

 

 

 

Note that the clearances shown are minimum for safety but do

 

 

 

 

 

 

 

 

 

 

 

not leave much room for access when cleaning or servicing.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

L

Rear

 

0"

 

 

200mm

 

 

 

 

 

 

Please take this into account when placing the stove.

 

 

 

 

 

 

 

 

 

 

 

 

 

Connect the power cord to a 120 V.A.C. 60Hz grounded

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

L

receptacle. (A surge protector is recommended to protect the

Floor protector

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

circuit board.) Also be sure that the polarity of the outlet that

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

the stove is plugged into is correct.

 

 

minimum: 32" X 32"

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Prior to installing the flue pipe, connect a draft meter. Turn the

(813mm X 813mm)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Feed Adjuster dial to "Test". Record the first reading. Connect

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

flue pipe to stove and be sure all doors and windows in the

NOTE: Measurement

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

home are closed. Record the second draft reading_______.

"K" is measured from

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

If the second reading is more than .05" lower than the first

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

the glass in the US

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

reading, check for possible restrictions or the need for outside

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ONLY

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

air (see page 10). For more information on the draft test

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

procedure, refer to Page 17.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Mobile Home Installation

 

 

 

 

 

 

 

 

 

 

 

 

 

J

 

 

 

K

 

 

 

J

When installing this unit in a mobile home several requirements

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

USA

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

must be followed (Reference HUD Regulation #24CFR3280):

 

 

 

 

 

 

 

 

 

 

Floor protector

 

 

 

 

CANADA

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1. The unit must be bolted to the floor. This can be done by

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

using clips (part # 2-00-677110B) and 1/4" lag screws.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2. The unit must be connected to outside air. See page 10.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3. Floor protection and clearances must be followed as shown

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

above.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

4. Unit must be grounded to the metal frame of the mobile

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

home.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

5. Chimney must meet requirements of CAN/ULC-S629,

 

 

 

 

 

18"/

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Standard for 650°C Factory Built Chimneys. Follow

 

 

 

 

 

 

457mm

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Manufacturer's guidelines concerning height and clearances

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

to combustibles. Use the same manufacturer's components

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

to provide an effective vapor barrier where the chimney or

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

other component penetrates to the the exterior of the mobile

 

 

 

 

 

6"/152mm

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

home. DO NOT MIX COMPONENTS FROM DIFFERENT

 

 

 

 

 

from pipe to

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

MANUFACTURERS. The top section of chimney and the

 

 

 

 

 

wall

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

chimney cap must be removable to a maximum height of 13.5'

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

for transport of the mobile home.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

4"/102mm

 

 

 

 

 

CAUTION: This appliance must be vented to the outside.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

from back of

 

 

 

 

 

CAUTION

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

top flue vent

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

to wall

 

 

 

 

 

THE STRUCTURAL INTEGRITY OF THE

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

MANUFACTURED HOME FLOOR, WALL, AND CEILING/

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ROOF MUST BE MAINTAINED.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

WARNING

DO NOT INSTALL IN A SLEEPING ROOM.

Fig. 5: Optional Top Vent Pipe Clearances

XXV Pellet Stove 7

Page 7
Image 7