Harman Stove Company R16 manual addendum

Models: R16

1 44
Download 44 pages 50.75 Kb
Page 31
Image 31
addendum

addendum

Minimizing Smoke during loss of Power using battery back-up

harmanTM strongly recommends installing battery back-up to minimize entry of smoke into the room in the event of power loss.

Your pellet/biomass burning appliance relies on a combustion blower to remove exhaust. A power failure will cause the combustion blower to stop. This may lead to exhaust seeping into the room. Vertical rise in the venting may provide natural draft. It is, however, no guarantee against leakage.

there are two harmanTM approved battery back-up options for your appliance:

uninterruptible Power Supply (uPS) UPS battery back-ups are available online or at computer and office equipment stores. Your HarmanTM appliance with Rev E or later software available beginning in November 2010 may be plugged directly into a HarmanTM approved UPS:

The APC (American Power Conversion) model #BE750G and the TrippLite model INTERNET750U are tested and approved. Other brands or models may not be compatible.

When power is lost, a fully charged UPS will power a safe, combustion blower only shut-down. Your appliance will pulse the blower every few seconds to clear exhaust until the fire is out. nOte: the uPS

provides safe shut-down only. it is not intended for continued operation.

Your appliance will recognize when power is restored. What happens depends on ESP temperature and whether it is equipped with automatic ignition:

in “automatic” setting, units equipped with automatic ignition will respond to the set point and ESP temperature and resume normal operation.

in “Manual” setting or for units without automatic ignition:

If the ESP is cool, the appliance will remain shut down.

If the fire is out and the ESP is still warm, the feeder may restart. Since the fire is out, the ESP temperature will not rise. The unit will then shut-down, and may flash a six-blink status error. (See ESP error codes)

If the fire is still burning, it will resume normal operation.

Contact your dealer if you have questions about UPS compatibility with your appliance.

harman Surefire 512h battery back-up The 512H connects to a 12 volt deep cycle battery that will run your appliance for up to eight (8) hours. It includes a trickle charge feature that keeps your battery charged when power is available. nOte: if the power is out for longer than battery life, smoke

leakage may still occur unless your stove has been safely shut down.

cautiOn! always keep appliance doors and hopper lid closed and latched during operation and during power failures to minimize risk of smoke or burn-back.

cautiOn! use only harmantM approved battery back-up devices. Other products may not operate properly, can create unsafe conditions or damage your appliance.

XXV Pellet Stove 31