Harman Stove Company TL2.0 manual 6Mobile Home, A. Mobile Home Installation

Models: TL2.0

1 40
Download 40 pages 37.87 Kb
Page 20
Image 20
6Mobile Home

6Mobile Home

TL2.0 Woodburning Stove

A. Mobile Home Installation

Mobile home approval - U.S. only.

DO NOT INSTALL IN A MOBILE HOME IN CANADA.

1.An outside air inlet must be provided for combustion air, and must remain clear of leaves, debris, ice, and/or snow. The outside air path must be unrestricted while the appliance is in operation. Use Kit #1-10-856082 to attach to unit.

2.The combustion air intake system must be of metal construction. It must permit zero-clearance to combustible materials, and contain a rodent screen.

3.The appliance must be secured to the mobile home structure by bolting it to the floor. There are holes provided in the pedestal base. Secure with the proper length lag bolts, through the hearth pad and into the home floor.

4.The appliance must be grounded to the metal framing of the mobile home

5.All clearances to combustibles and floor protection requirements must be followed.

6.Follow the vent manufacturer's instructions when installing in a mobile home. Must be connected to a UL103 HT ventillated chimney connector, UL103 HT chimney, and terminal cap with spark arrestor.

7.Use silicone to create an effective vapor barrier at the location where the chimney or other component penetrates to the exterior.

8.Installation shall be in accordance with the Manufactured Home and Safety Standard (HUD) CFR 3280, Part 24

9.The appliance must never be installed in a room designated for sleeping.

10.Burn wood only. Other fuels may generate poisonous gases (carbon monoxide).

11.If unit burns poorly while an exhaust blower (range hood) is operating, increase the supply of combustion air to the appliance

Caution

the structural integrity of the mobile home floor, wall and ceiling/roof must be maintained.

Do NOT cut through:

Floor joist, wall studs, or ceiling trusses.

Any supporting material that would affect the structural integrity.

NOTE: The top sections of the chimney must be removable to allow a maximum clearance of 13.5 feet (411cm) from ground level for transportation purposes.

 

Chimney Cap

Chimney

Storm Collar

Sections

Roof Flashing

 

 

Roof

 

Radiation

Attic

Shield

 

Radiation

 

Shield

 

Minimum Air Space

Chimney

with Chimney Listing

Support

Chimney

Connector

Outside

Air

A. Mobile Home Installation warning

Installation must comply with

Manufactured Home and Safety Standard

(HUD), CFR 3280, Part 24.

Manual background warning

Do not install in sleeping room.

20 Dry Seasoned Wood Only!

3-90-08560

Save These Instructions