Harman Stove Company TL2.0 manual Special Note, 2Special Warnings and Notes

Models: TL2.0

1 40
Download 40 pages 37.87 Kb
Page 5
Image 5
2Special Warnings and Notes

TL2.0 Woodburning Stove

2Special Warnings and Notes

Carbon monoxide, referred to as CO, is a colorless, odorless gas that is produced during combustion of wood and other fuels. CO fumes are toxic and can be fatal.

This appliance is a natural draft system which relies on a properly designed chimney to remove CO and other combustion by-products from the stove.

Even though this stove is designed to be as safe as possible, it is important that you install a CO detector. This is true for oil, gas, or coal burning products as well.

CO is not specifically heavier or lighter than air. Therefore, it is best to install the detector at table top level rather than on the ceiling like a smoke detector.

CO detectors are very sensitive and may sound an alarm for fumes other than CO or CO from sources other than the stove such as car or lawn mower exhaust.

If the alarm sounds

1.Increase ventilation by opening windows or doors.

2.Make sure the stove doors and lid are closed and latched.

3.Check stove for smoking or puffing condition. Open by-pass and increase air-flow to firebox, if needed.

4.Check chimney for possible blockage or down-draft.

5.Check for false alarm.

Never use gasoline, lantern fuel, kerosene, charcoal lighter fluid, or similar liquids to start or “freshen up” a fire in this heater. Keep all such liquids well away from the heater while it is in use.

SPECIAL NOTE:

Due to ash buildup, it is strongly recommended to have your stove professionallycleanedand serviced annually. This includes all parts of the stove, and the venting system.

NEVER CONNECT THIS UNIT TO A CHIMNEY FLUE SERVING ANOTHER APPLIANCE.

Installation and repair of this stove should be done by a qualified service person. We recommend that the stove be inspected before use and at least annually by a qualified service person. Periodic cleaning is required throughout the heating season and at the end of each winter for the stove to work efficiently.

DO NOT CONNECT TO ANY AIR DISTRIBUTION DUCT OR SYSTEM.

Save These Instructions

3-90-08560

Dry Seasoned Wood Only!

5

Page 5
Image 5
Harman Stove Company TL2.0 manual Special Note, 2Special Warnings and Notes