12

Verifying Operation of the Lift

Caution: Complete the following section before training the customer to use the lift.

Step 1

Run the lift up and down for 5 complete cycles. Hold the direction button down and allow the limit switches to stop the lift. At the top, verify that the platform stops level with the upper landing. At the bottom, verify the access ramp unfolds and rests on the ground.

Step 2

Verify the operation of the Emergency stop switch. When this switch is pushed the lift should not run in either direction. When this switch is pulled back out, the lift should operate normally.

Step 3

Verify the operation of the sensor pan underneath the platform. Start with the lift at the top landing. Press up on the sensor pan. While holding the pan in this location, press the down switch on the platform. The lift should not run.

Warning: Do not run the lift if anyone is under the platform.

Page 12
Image 12
Harmar Mobility RPL600, RPL400 manual Verifying Operation of the Lift