9

Anchoring the Lift

Step 1

Position the lift in its final location.

Verify that it is level and perpendicular to its surroundings.

Shim if necessary.

Anchors

Harmar recommends securing the lift using our Anchor Kit. If you purchase you own floor anchors they must use 1/2-13 bolts and have a minimum tensile strength of 6000 LBS.

Warning: All four floor anchors must be installed correctly in accordance to

their instructions.

Step 2

Use the lift’s base as a template. Drill 4 holes into the concrete.

Verify that the holes you have drilled are deep enough to accept the anchors.

Tip: Concrete dust may have settled into the holes you just drilled. Use a shop vacuum to clean out these holes. This will ensure the floor anchors set correctly.

Step 3

Secure the lift in place by tightening the floor anchor bolts.

Page 9
Image 9
Harmar Mobility RPL400, RPL600 manual Anchoring the Lift, Step