Harmar Mobility RPL400, RPL600 manual Top Landing EMI Interlock optional

Models: RPL600 RPL400

1 22
Download 22 pages 53.9 Kb
Page 15
Image 15

15

Top Landing EMI Interlock (optional)

The optional EMI Interlock is provided with a combination mechanical lock and electric contact. They are to be used with existing doors.

The interlock:

Prevents the lift from running if the door is not closed.

Prevents the door from being opened if the platform is not at the landing.

Unlocks when the lift is on the landing limit switch.

EMI Interlock

1)Position interlock to door jamb and mark mounting holes.

2)Fasten Interlock to door jamb with #8 wood screws.

3)Route 4-conductor Interlock cable thru hole in top of interlock and make wire connections.

4)Attach door keeper and emergency key plates to hoistway door.

.

Alength of multi‐conductor wire will need to be ran from the bottom of the lift tower to the interlock. Consult local codes for type and mounting requirements. After wiring is completed, the wiring harness must be plugged into it appropriate receptacle on the controller (ref pg 5).

Wiring Connections

EMI

Lift Harness

Black (A)

Orange

Black (B)

Green

Yellow (C)

Black

Yellow (D)

Brown

Page 15
Image 15