Harmar Mobility RPL600, RPL400 manual Setting the Limit Switches

Models: RPL600 RPL400

1 22
Download 22 pages 53.9 Kb
Page 10
Image 10

10

Setting the Limit Switches

Your lift is equipped with upper and lower limit switches. The vertical location of these switches may be adjusted to fit your application.

Typically the upper limit switch will need to be adjusted so the platform will stop level with the upper landing. The lower limit will typically not need adjusting.

Step 1

Verify the emergency switch is in the ON position. Run the lift in the up direction until the platform floor is level with the upper landing.

1A Unplug the lift’s power cord from the wall before going to the next step (AC units).

1B Uplug the power cable from the battery box before going to the next step (DC units).

Warning: Moving components can cut and crush. Do not operate the lift if you are in close proximity to any drive components. Be aware that loose clothing or jewelry may catch on moving parts.

Step 2

Remove the screws at the top of the lift that attach the front cover.

Step 3

Remove the front cover by tilting it forward and lifting upwards. The bottom of the front cover sets on a pin on either side of the lift frame. Set the cover aside in a safe location where it will not get damaged.

Page 10
Image 10
Harmar Mobility RPL600, RPL400 manual Setting the Limit Switches