SPECIFICATIONS
ELECTRICAL RATING CHART – 3CS2 MODELS
|
| Kilowatts |
|
| Wire Sizing |
Model | Voltage | (kW) | Phase | Amps | AWG*† |
208 | 3 | 1 | 14.5 | 12 | |
208 | 4 | 1 | 19.2 | 12 | |
208 | 6 | 1 | 28.8 | 10 | |
240 | 3 | 1 | 12.5 | 12 | |
240 | 4 | 1 | 16.7 | 12 | |
240 | 6 | 1 | 25.0 | 10 | |
208 | 3 | 3 | 8.4 | 14 | |
208 | 4 | 3 | 11.2 | 14 | |
208 | 6 | 3 | 16.7 | 12 | |
240 | 3 | 3 | 7.3 | 14 | |
240 | 4 | 3 | 9.6 | 14 | |
240 | 6 | 3 | 14.5 | 12 | |
208 | 8 | 1 | 38.4 | 8 | |
240 | 8 | 1 | 33.3 | 8 | |
208 | 9 | 3 | 25.0 | 10 | |
240 | 9 | 3 | 21.7 | 10 | |
208 | 12 | 3 | 33.4 | 8 | |
240 | 12 | 3 | 29.0 | 10 |
Fuse or
Circuit Breaker*
20
30
40
20
30
40
15
15
30
15
15
20
50
50
40
30
50
40
Shipping Weight
24 lbs. (11 kg)
24 lbs. (11 kg)
27 lbs. (12 kg)
24 lbs. (11 kg)
24 lbs. (11 kg)
27 lbs. (12 kg)
24 lbs. (11 kg)
24 lbs. (11 kg)
27 lbs. (12 kg)
24 lbs. (11 kg)
24 lbs. (11 kg)
27 lbs. (12 kg)
27 lbs. (12 kg)
27 lbs. (12 kg)
27 lbs. (12 kg)
27 lbs. (12 kg)
27 lbs. (12 kg)
27 lbs. (12 kg)
* Based upon NEC 2002 Code
† Based upon THHN wire rated 90ºC.
Form No. | 4 |