ELECTRICAL RATING CHART – 3CS2 MODELS

SPECIFICATIONS

ELECTRICAL RATING CHART – 3CS2 MODELS

 

 

Kilowatts

 

 

Wire Sizing

Model

Voltage

(kW)

Phase

Amps

AWG*†

3CS2-3

208

3

1

14.5

12

3CS2-4

208

4

1

19.2

12

3CS2-6

208

6

1

28.8

10

3CS2-3

240

3

1

12.5

12

3CS2-4

240

4

1

16.7

12

3CS2-6

240

6

1

25.0

10

3CS2-3B

208

3

3

8.4

14

3CS2-4B

208

4

3

11.2

14

3CS2-6B

208

6

3

16.7

12

3CS2-3B

240

3

3

7.3

14

3CS2-4B

240

4

3

9.6

14

3CS2-6B

240

6

3

14.5

12

3CS2-8

208

8

1

38.4

8

3CS2-8

240

8

1

33.3

8

3CS2-9B

208

9

3

25.0

10

3CS2-9B

240

9

3

21.7

10

3CS2-12B

208

12

3

33.4

8

3CS2-12B

240

12

3

29.0

10

Fuse or

Circuit Breaker*

20

30

40

20

30

40

15

15

30

15

15

20

50

50

40

30

50

40

Shipping Weight

24 lbs. (11 kg)

24 lbs. (11 kg)

27 lbs. (12 kg)

24 lbs. (11 kg)

24 lbs. (11 kg)

27 lbs. (12 kg)

24 lbs. (11 kg)

24 lbs. (11 kg)

27 lbs. (12 kg)

24 lbs. (11 kg)

24 lbs. (11 kg)

27 lbs. (12 kg)

27 lbs. (12 kg)

27 lbs. (12 kg)

27 lbs. (12 kg)

27 lbs. (12 kg)

27 lbs. (12 kg)

27 lbs. (12 kg)

* Based upon NEC 2002 Code

† Based upon THHN wire rated 90ºC.