Hearth and Home Technologies 7100, 9100 manual 4 10.6 mm, Air Shutter Adjustment oven burner only

Models: 9100 7100

1 38
Download 38 pages 20.14 Kb
Page 30
Image 30
Air Shutter Adjustment (oven burner only)

Air Shutter Adjustment (oven burner only)

The quality of the flame can be changed by adjusting the air shutters. Factory setting on the air shutter is 0.40" (10.6mm). (see figure 9)

loosen screw

Reduce the shutter opening if:

the flame appears unsteady

is not burning all the way around

is noisy like a small blow torch.

Increase the shutter opening if:

the flame has yellow tips

there is no sharp blue cone

soot appears on the bottom of cooking pans.

.4"

10.6 mm

air shutter adjustment Figure 9

The oven burner air shutter is located at the base of the burner inside the broiler compartment. It can not be adjusted in place and the oven bottom must be removed to reach it. The burner must be removed to adjust shutter.( see page 30 for burner removal)

The air shutter is adjusted by loosening the locking screw and rotating the shutter to allow more or less air into the tube. The centred position is usually about right. Tighten the screw, replace the assembly and check the flame pattern.

Oven Burner Assembly

The oven burner assembly is visible and accessible for servicing when the oven bottom panel is removed. The burner assembly is made up of several components as shown below.

thermocouple

burner

igniter

Oven burner assembly

Figure 10

1/8" Critical

3/16" .4"Oven Burner Assembly3.0mm 4.7mm figure 11)

IMPORTANT

The thermocouple and igniter positioning is very important to the operation of the oven. These two items must be checked before putting the appliance into operation. (see

figure 11)

NOTE: Before putting the 7100 /9100 Gas Range into service, be sure that all the setup procedures recommended in this manual have been completed.

Top View

Side View

Thermocouple

3.0mm1/8"Critical

The oven ignitor must be on the centre of the pipe in the middle of the first and second port

figure 11

26

Page 30
Image 30
Hearth and Home Technologies 7100, 9100 manual 4 10.6 mm, Air Shutter Adjustment oven burner only, Oven Burner Assembly