Hearth and Home Technologies BE-36-C Framing the Fireplace for DVP-Series and SL D-Series Pipe

Models: BE-36-C BE-36-CIPI

1 37
Download 37 pages 30.79 Kb
Page 12
Image 12

Step 2. Framing the Fireplace for DVP-Series and SL D-Series Pipe

Fireplace framing can be built before or after the fireplace is set in place. Framing should be positioned to accommo- date wall coverings and fireplace facing material. The dia- gram below shows framing reference dimensions.

CAUTION: MEASURE FIREPLACE DIMENSIONS AND VERIFY FRAMING METHODS AND WALL COVERING DETAILS BEFORE FRAMING.

Framing should be constructed of 2 X 4 lumber or heavier. The framing headers may rest on the

VENTfireplace stand-offs.

FRAMING

HOLE

E D

A B C D* E*

37” 33” 16 1/4” 36 1/2” 24 3/8

*The center of the framing hole is one inch (25.4mm) above the center of the horizontal vent pipe.

WARNING:

To ensure proper clearances the front framing header must be installed on its narrow edge and to the front of the frame.

B

C

A

Figure 3. Framing Dimensions for SL D-Series and DVP-Series Pipe

12

Hearth & Home Technologies • BE-36-C, BE-36-CIPI397-981 Rev. R • 2/05

Page 12
Image 12
Hearth and Home Technologies BE-36-CIPI manual Framing the Fireplace for DVP-Series and SL D-Series Pipe, C D* E