Hearth & Home Technologies • BE-36-C, BE-36-CIPI • 397-981 Rev. R • 2/05 19

Figure 13.

Venting with Two 90° Elbows

BE-36-C
V (MIN.) H + H1 (MAX.)
90o Elbow on Top 2.5' (863mm)
1' (305mm) 3' (914mm)
2' (610mm) 4' (1.22m)
3' (914mm) 6' (1.86m)
4' (1.22m) 8' (2.48m)
5' (1.52m) 16' (4.8m)
H + H1 MAX. = 16' (4.8m)
V + H + H1 MAX. = 40' (12.2m)
BE-36-C
V (MIN.) H (MAX.)
90o Elbow on Top 2.5' (863mm)
1' (305mm) 3' (914mm)
2' (610mm) 4' (1.22m)
3' (914mm) 6' (1.86m)
4' (1.22m) 8' (2.48m)
5' (1.52m) 16' (4.8m)
H MAX. = 16' (4.8m)
V + V1 + H MAX. = 40' (12.2m)
Use SL D-Seriescomponents only.
BE-36-C LP
H+H1 (MAX.)
2.5' (863mm)
2.5' (863mm)
4' (1.22m)
6' (1.86m)
8' (2.48m)
16' (4.8m)
BE-36-C LP
H (MAX.)
2.5' (863mm)
2.5' (863mm)
4' (1.22m)
6' (1.86m)
8' (2.48m)
16' (4.8m)
H
V
V
1
NOTE: There MUST be a 25% reduc-
tion in total H when using flex vent
except when using the simple up
and out installation (see Figure 7).

V

H

H

1