Hearth & Home Technologies • BE-36-C, BE-36-CIPI • 397-981 Rev. R • 2/05 21
Use SL D-Series
components only.
BE-36-C
H + H1 (MAX.)
4' (1.22m)
6' (1.86m)
8' (2.48m)
12' (3.72m)
16' (4.8m)
16' (4.8m)
Figure 15. Venting with Three 90° elbows

H + H1 MAX. = 16' (4.8m)

V + H + V1 + H1 MAX. = 40' (12.2m)

BE-36-C LP
H + H1 (MAX.)
5' (1.52m)
5' (1.52m)
8' (2.48m)
12' (3.72m)
16' (4.8m)
16' (4.8m)
Use SL D-Series
components only.

H + H1 MAX. = 16 FT (4.8m)

V + V1 + H + H1 MAX. = 40 FT (12.2m)

BE-36-C
V (MIN.) H + H1 (MAX.)
90o Elbow on Top 2.5' (863mm)
1' (305mm) 3' (914mm)
2' (610mm) 4' (1.22m)
3' (914mm) 6' (1.86m)
4' (1.22m) 8' (2.48m)
5' (1.52m) 16' (4.8m)
BE-36-C LP
H + H1 (MAX.)
2.5' (863mm)
2.5' (863mm)
4' (1.22m)
6' (1.86m)
8' (2.48m)
16' (4.8m)
V
1
H
1
H
V
BE-36-C, BE-36-C LP
V (MIN.) H (MAX.)
90o
Elbow on Top
2.5' (863mm)
1' (305mm) 2.5' (863mm)
2' (610mm) 4' (1.22m)
3' (914mm) 6' (1.86m)
4' (1.22m) 8' (2.48m)
5' (1.52m) 16' (4.8m)

NOTE: There MUST be a 25% reduc-

tion in total H when using flex vent

except when using the simple up and

out installation (see Figure 7).

H
1
H
V
1
V