Hearth & Home Technologies • BE-36-C, BE-36-CIPI • 397-981 Rev. R • 2/05 29
!
Step 4. Positioning, Leveling, and Securing the Fireplace
Place the fireplace into position.
Level the fireplace from side to side and from front to
back.
Shim the fireplace with non-combustible material, such
as sheet metal, as necessary.
Secure the fireplace to the framing by nailing or screwing.
!
!
The diagram below shows how to properly position, level,
and secure the fireplace.
Figure 28. Proper Positioning, Leveling, and
Securing of a Fireplace
Figure 29. Gas Control System
STANDING PILOT and IPI
Step 5. The Gas Control System
WARNING: THIS UNIT IS NOT FOR USE WITH
SOLID FUEL.
The gas control system used with model BE-36-C is
Standing Pilot Ignition.
Standing Pilot Ignition System
This system includes millivolt control valve, standing pilot,
thermopile/thermocouple flame sensor, and piezo ignitor.
WARNING: 110-120 VAC MUST NEVER BE
CONNECTED TO A CONTROL VALVE IN A
MILLIVOLT SYSTEM.

3/8” (10mm)

WARNING:
To ensure proper
clearances the
front framing
header must be
installed on its
narrow edge and
to the front of
the frame.
NAILING TABS
(BOTH SIDES)
The gas control system used with model BE-36-CIPI is
Intermittent Pilot Ignition (IPI).
Intermittent Pilot Ignition (IPI) System
This system includes a 3V control valve, electronic module
and intermittent pilot.
WARNING: 110-120 VAC SER VICE MUST BE
WIRED TO THE FIREPLACE JUNCTION BOX.