Hearth and Home Technologies CD4236R, CD4842ILR, CD4842R Construct the Appliance Chase, Clearances

Models: CD4842R CD4842LR CD4236ILR CD4236LR CD4842IR CD4842ILR CD4236R CD4236IR

1 80
Download 80 pages 41.85 Kb
Page 19
Image 19

B. Construct the Appliance Chase

A chase is a vertical box-like structure built to enclose the gas appliance and/or its vent system. In cooler climates the vent should enclosed inside the chase.

NOTICE: Treatment of ceiling firestops and wall shield firestops and construction of the chase may vary with the type of building. These instructions are not substitutes for the requirements of local building codes. Therefore, you MUST check local building codes to determine the requirements to these steps.

Chases should be constructed in the manner of all out- side walls of the home to prevent cold air drafting prob- lems. The chase should not break the outside building envelope in any manner.

Walls, ceiling, base plate and cantilever floor of the chase should be insulated. Vapor and air infiltration barriers should be installed in the chase as per regional codes for the rest of the home. Additionally, in regions where cold air infiltration may be an issue, the inside surfaces may be sheetrocked and taped for maximum air tightness.

To further prevent drafts, the wall shield and ceiling fire- stops should be caulked with high temperature caulk to seal gaps. Gas line holes and other openings should be caulked with high temp caulk or stuffed with unfaced insu- lation. If the appliance is being installed on a cement slab, a layer of plywood may be placed underneath to prevent conducting cold up into the room.

C. Clearances

NOTICE: Install appliance on hard metal or wood surfaces extending full width and depth. DO NOT install directly on carpeting, vinyl, tile or any combustible material other than wood.

WARNING! Risk of Fire! Maintain specified air space clearances to appliance and vent pipe:

Insulation and other materials must be secured to prevent accidental contact.

Failure to maintain airspace may cause overheating and a fire.

1/2 in. (13 mm)

1/2 in. (13 mm)

Drywall

0 in.

Combustible flooring may be installed next to the front of the appliance.

30in.

(762 mm)

to ceiling

0 in. to level

 

of standoffs

D

B

C

A

Object

 

36 in.

 

 

 

Combustible

 

(914 mm)

 

 

 

0 in. to

 

 

 

 

 

 

 

 

floor

 

 

 

 

 

Figure 5.2 Clearances to Combustibles

Note: Adjust framing dimensions for interior sheathing (such as sheetrock)

 

 

A

B

C

D

D

 

 

Rough

Rough

Rough

Rough

Rough

 

 

Opening

Opening

Opening

Opening

Opening

Model

 

(Width)

(Height)

(Depth)

(DVP Pipe)

(SLP Pipe)

CD4236

in.

42

38.75

23

10

9

 

 

 

 

 

 

 

 

mm

1067

984

584

254

229

CD4842

in.

48

38.75

23

10

9

 

 

 

 

 

 

 

 

mm

1219

984

584

254

229

Heatilator • Caliber CD Series • 4040-263 Rev N • 11/08