R

Cumberland Gap Wood Stove

REVERSIBLE FLUE COLLAR

The flue collar is reversible for either a top or rear venting installation. The unit is shipped with the flue collar in the top vent position.

ACCESSORY HORIZONTAL FLUE SHIELD

Part HTSHLD-7006

IS REQUIRED ON ALL HORIZONTAL INSTALLATIONS.

CONVERTING COLLAR FOR REAR VENT INSTALLATION

 

1. Lift off cast top. Remove 4 Phillips head screws from the

 

 

heat shield and discard heat shield. See circled areas in

 

 

Figure 10A.

 

2.

Remove 4 Phillips head screws from the rear shield, 2

 

 

on each side, lift rear heat shield off and set aside.

 

3.

Remove 1 bolt from each side of the flue collar using a

 

 

Phillps head screwdriver and 7/16 wrench.

 

4.

Turn flue collar to horizontal position. Inspect sealant to

 

 

ensure a leak free application. Re-attach bolts.

 

5.

Re-attach the rear heat shield.

 

6.

Attach required accessory Horizontal Flue Shield with

Figure 10B

 

screws provided. Figure 10B

 

7.Place cast top on the unit. See Figure 10C for completed view.

Secure

Horizontal Flue

Heat Shield

Remove cast top

Completed View

Figure 10A

Remove bolts and

rotate flue collar

Discard heat shield

Rear Heat

Shield

Remove 4 screws and set rear shield & screws aside

Figure10C

Page 10

7006-188E

September 1, 2008

Page 10
Image 10
Hearth and Home Technologies CUMBGAP-MBK Reversible Flue Collar, Completed View, Accessory Horizontal Flue Shield