R

Cumberland Gap Wood Stove

LOCATING YOUR STOVE

WHEN LOCATING YOUR STOVE consider safety, convenience, traffic flow, and the fact that the stove will need a chimney and chimney connector. It is a good idea to plan your installation on paper, using exact measurements for clearances and floor protection, before actually beginning the installation. If you’re not using an existing chimney, place the stove where there will be a clear passage for a factory-built listed chimney through the ceiling and roof.

AVOID FIRE: Maintain the designated clearances to combustibles. Insulation must not touch the chimney. You must maintain the designated air space clearance around the chimney. This space around a chimney is necessary to allow natural heat removal from the area. Insulation in this space will cause a heat buildup, which may ignite wood framing. NOTE: Clearances may only be reduced by means approved by the regulatory authority having jurisdiction.

WE RECOMMEND that you have a qualified building inspector and your insurance company representative review your plans before and after installation.

IMPORTANT!

If stove is relocated it must meet minimum required clearances in new location to use the side fuel loading door or door must be locked in place.

SIDE FUEL-LOADING-DOOR LOCKING MECHANISM

The side fuel-loading-door is shipped locked in place. You must first decide where you are locating your stove and determine if you meet the minimum required clearances from combustibles for loading wood into the firebox from the side door. If you do not meet the clearances found on pages 6-8, leave the door locked in place. If you unlock the door without meeting the minimum requried clearances YOU WILL VOID YOUR WARRANTY AND ASSUME ALL RESPONSIBILITY. If you do meet the minimum clearances, follow the steps to unlock the door. If in the future you decide to relocate your stove, again determine if you meet the mimimum required clearances to combustibles in the new location. If you do not, you are required to lock the door shut and it must remain locked at all times.

UNLOCK SIDE FUEL DOOR

1.Open front doors.

2.Using a 5-32 Allen wrench, remove the bolt from the lock- ing bracket.

3.Save the bracket and bolt for potential future use.

LEG LEVELING SYSTEM

1.Thread Allen bolts through nuts until flush. Figure 9A. The Allen bolts and nuts are included in the component pack inside the stove firebox.

2.Slide assembled nuts and bolts into slots on legs with the nuts on the bottom. Figure 9B. Use a 5-32" (4mm) Allen wrench to adjust legs up and down to desired level. Figure 9C

Figure 9A

Figure 9B

Fig 9C - Bolt fully extended

September 1, 2008

7006-188E

Page 9

Page 9
Image 9
Hearth and Home Technologies CUMBGAP-PMH, CUMBGAP-MBK Locating Your Stove, Side FUEL-LOADING-DOOR Locking Mechanism