Hearth and Home Technologies Cyclone-Cust Vent Information and Diagrams, A. Vent Table Key

Models: Cyclone-Cust

1 46
Download 46 pages 42.76 Kb
Page 12
Image 12
5 Vent Information and Diagrams

5 Vent Information and Diagrams

A. Vent Table Key

The abbreviations listed in this vent table key are used in the vent diagrams.

Symbol

Description

V1

First section (closest to appliance) of vertical length

 

 

V2

Second section of vertical length

 

 

H1

First section (closest to appliance) of horizontal length

 

 

H2

Second section of horizontal length

 

 

A. Vent Table Key WARNING

Fire Hazard. Explosion Risk. Asphyxiation Risk.

Do NOT connect this gas appliance to a chimney flue serving a separate solid-fuel or gas burning appliance.

• Vent this appliance directly outside.

• Use separate vent system for this appliance.

May impair safe operation of this appliance or other appliances connected to the flue.

B. Use of Elbows

CAUTION

ALL vent configuration specifications MUST be followed.

This product is tested and listed to these specifications.

Appliance performance will suffer if specifications are not followed.

Diagonal runs have both vertical and horizontal vent as- pects when calculating the effects. Use the rise for the vertical aspect and the run for the horizontal aspect (see Figure 5.1).

Two 45º elbows may be used in place of one 90º elbow. On 45º runs, one foot of diagonal is equal to 8.5 inches hori- zontal run and 8.5 inches vertical run. A length of straight pipe is allowed between two 45º elbows (see Figure 5.1).

Verticalin. 1/2-8

8-1/2 in.

B. Use of Elbows HorizontalVerticalin. 1/2-8

Figure 5.1

C. Measuring Standards

Vertical and horizontal measurements listed in the vent diagrams were made using the following standards.

1.Pipe measurements are shown using the effective length of pipe (see Figure 5.2).

2.Measurements are made from the appliance outer wrap, not from the standoffs.

3.Horizontal terminations are measured to the outside mounting surface (flange of termination cap) (see Figure 4.1).

4.Vertical terminations are measured to bottom of termi- nation cap.

5.Horizontal pipe installed level with no rise.

 

Pipe

Effective Length

 

Inches

Millimeters

 

 

 

DVP4

4

102

 

DVP6

6

152

Effective

DVP12

12

305

Height/Length

DVP24

24

610

 

 

DVP36

36

914

 

DVP48

48

1219

 

DVP6A

3 to 6

76 to 152

 

DVP12A

3 to 12

76 to 305

 

DVP12MI

3 to 12

76 to 305

 

DVP24MI

3 to 24

76 to 610

Figure 5.2 DVP Pipe Effective Length

 

 

12

Heat & Glo • Cyclone-Cust2061-900 Rev. L • 10/08

Page 12
Image 12
Hearth and Home Technologies Cyclone-Cust owner manual Vent Information and Diagrams, A. Vent Table Key, B. Use of Elbows