Hearth and Home Technologies Cyclone-Cust owner manual B. Connecting to the Appliance

Models: Cyclone-Cust

1 46
Download 46 pages 42.76 Kb
Page 29
Image 29
B. Connecting to the Appliance

B. Connecting to the Appliance

C. Hot Surface Ignition Wiring WARNING

Wire 110V to terminal block.

Do NOT wire 110V to valve.

Do NOT wire 110V to wall switch.

Incorrect wiring will damage this valve.

Incorrect wiring will override HSI safety lockout and may cause explosion.

This appliance comes factory wired with a remote control for operation. The remote can be removed and the appliance can be wired to run off of a standard wall switch. Refer to the wiring diagram for more information.

Keep wire lengths short as possible by removing any excess wire length.

Low voltage and 110 VAC voltage cannot be shared within the same wall box.

C. Hot Surface Ignition Wiring

This appliance requires a 110 VAC supply to the appli- ance terminal block for operation. A wiring diagram is shown in Figure 10.9. This appliance is equipped with a 24V valve.

Optional Accessories Requirements

Wiring for optional accessories should be done now to avoid reconstruction.

CAUTION

Label all wires prior to disconnection when servicing controls. Wiring errors can cause improper and dangerous operation. Verify proper operation after servicing.

Optional Accessories Requirements WARNING

Shock hazard.

Replace damaged wire with type 105º C rated wire.

Wire must have high temperature insulation.

 

 

 

 

GROUND

FAN MOTOR

 

 

 

 

 

 

 

 

 

(L1) 120-BLACK

 

 

 

 

 

(N) NEUTRAL-WHITE

 

REMOTE

 

 

 

 

 

 

 

8

 

 

 

 

 

24 VOLT TRANS

3

 

 

 

2

 

 

 

2

 

 

 

 

 

 

 

1

5

 

 

 

 

 

 

SENSOR

 

 

 

 

 

 

 

 

9

 

 

7

6

 

 

 

 

 

 

 

 

 

 

 

CONTROL MODULE

 

 

 

 

 

 

4

 

 

HOT SURFACE IGNITOR

1

 

 

3

 

(HSI)

 

 

 

 

 

 

 

 

 

ITEM

PART DESCRIPTION

 

COLOR(S)

 

 

1

(M)L1 - (M)F1 - (T) 23 - -120V

 

Black

 

 

2

(FT) BTM-IGN-(T)1- +120V

 

Black/White

 

 

3

(V)1 & (V)3 - GND & (T)4

 

Blue/Green

 

 

4

(V)2 & (V)4 - (M)MV1

 

Red

 

 

5

(M) F2 - (FT) TOP

 

White

 

 

6

(M)S1-IGN

 

White

 

 

7

FEMALE RECEPTACLE PLUG

 

Black/White/Green

 

 

8

REMOTE WITH PIGTAIL - (M)W OPTIONAL

Red

 

Figure 10.9 Wiring diagram

9

(M)R - (M)W - (M)P.SW - REM/WS

 

Red

 

 

 

 

 

 

 

Heat & Glo • Cyclone-Cust2061-900 Rev. L • 10/08