A. Valve Access and Service

The gas valve can be accessed behind the cement refractory panel on the right side of the fireplace.

Lift doors out and set aside. There is a washer under each door. Be careful not to lose the washers.

WASHER

Figure 11.1 Lift Out Doors

Remove logs if access is necessary after installation is complete. See Section 9.C. Remove logs in reverse order of set up.

Remove grate if access is necessary after installation is complete. (Refer to Section 9.B.)

Remove two screws on side of pilot shield and remove shield.

Figure 11.2 Remove Pilot Shield

Use a phillips screwdriver to remove the two screws securing the refractory retaining strip. Remove the refractory side panel and set aside.

Figure 11.3 Loosen Refractory Retaining Strip

Remove the inside valve access panel by lifting it up and out.

Figure 11.4 Remove Valve Access Panel

Use a phillips screwdriver to remove the exterior valve access panel (remove four screws).

Figure 11.5 Remove Exterior Valve Access Panel

Loosen lower pressure tap screw before attaching manometer. Start up the fireplace to verify the pressure and adjust as necessary. Reverse these steps to reassemble before log positioning.

Note: Pressure tap screws must be re-tightened.

Figure 11.6 Connect Manometer

Heat & Glo Lifestyle Collection • Dakota 42-CE4036-915 Rev I • 11/07

21

Page 21
Image 21
Hearth and Home Technologies Dakota 42-CE manual Valve Access and Service, Washer