4 Fireplace Locations

A. Fireplace Minimum Clearances

D

E

G

FP

A

R

H

O

P

N

FP

Q

(See Note 2)

L

B

B

FP

F FP

FP

B

 

 

FP

I M

FP X

A

FP = FIREPLACE OPENING

X = AIR SUPPLY INLET

J or K

= AREAWHERE FIREPLACE IS NOT PERMITTED

A

=

0 cm

clearances above grade,

 

 

(See note 1)

veranda, porch, deck or

 

 

 

balcony.

B

=

30.5 cm . . . . . . . clearances to window or door

 

 

 

that may be opened, or to

 

 

 

permanently closed window.

 

 

91.4 cm

vinyl windows or siding.

D**

= 119.3 cm . . . . . . . vertical clearance to unventi-

 

 

 

lated soffit or to ventilated soffit

 

 

 

located above the terminal.

 

 

152.4 cm

vinyl clad soffits.

F

=

22.8 cm

clearance to outside corner.

G*

=

15.2 cm

clearance to inside corner.

 

 

121.9 cm

vinyl windows or siding.

H

=

91.5 cm

not to be installed above a gas

 

 

 

meter/regulator assembly within

 

 

 

91.5 cm horizontally from the

 

 

 

center line of the regulator.

I

=

91.4 cm

clearance to service regulator

 

 

 

vent outlet and electric service.

J= 22.8 cm . . . . . clearance to non-mechanical air supply inlet to building or the combustion air inlet to any other appliance.

K= 91.4 cm . . . . . clearance to a mechanical air supply inlet.

L*** = 2.1 M . . . . . . clearance above paved sidewalk

(See note 1) or a paved driveway located on public property.

M****= 119.3 cm . . . . . clearance under veranda, porch, deck, balcony or overhang.

 

Not allowed:

vinyl

N

=

15.2 cm . . . . . non-vinyl siding.

P

=

213.3 cm

 

*122 cm minimum for vinyl windows or vinyl siding.

**Not allowed for vinyl clad soffits.

***a fireplace shall not open directly above a sidewalk or paved driveway which is located between two single family dwellings and services both dwellings.

fireplace and termination. 2) All mechanical air intakes within 3.0 M of a termination must be a minimum of 0.91 M below the fireplace hood. 3) All gravity air intakes within 0.91 M of the fireplace hood must be a minimum of 2.54 cm below the termina- tion.

****only permitted if veranda, porch, deck or balcony is fully open on a minimum of 2 sides beneath the floor, or if the screened porch guidelines are followed.

Note 1: Local codes or regulations may require different clearances.

Note 2: Termination in an alcove space (spaces open only on one side and with an overhang) are permitted with the dimensions specified for vinyl or non-vinyl siding and soffits. 1) There must be a 0.91 M minimum between terminations or between the

 

 

QMIN

RMAX

Dakota

3.0 M

2 x Q ACTUAL

1

additional termination cap

Q + 0.91 M

1 x Q ACTUAL

2

additional termination caps

Q + 1.83 M

2/3 x Q ACTUAL

3

additional termination caps

Q + 2.74 M

1/2 x Q ACTUAL

RMAX = (2 / # caps plus fireplace ) x QACTUAL

Figure 4.1 Minimum Clearances

Heat & Glo Lifestyle Collection • Dakota 42-CE4036-915 Rev I • 11/07

7

Page 7
Image 7
Hearth and Home Technologies Dakota 42-CE manual Fireplace Locations, Fireplace Minimum Clearances