6 Gas Information
A. Gas Pressure Requirements | B. Gas Connection |
Pressure requirements for Heat & Glo gas fireplaces are shown in Table 1 below.
Two taps are provided on the outlet side of the gas control for a test gauge connection to measure the inlet and outlet pressures. These inlet and outlet pressure taps can be ac- cessed through the internal valve access panels as shown in Section 11: Maintaining and Servicing the Fireplace.
The fireplace and its individual
If the fireplace must be isolated from the gas supply piping system by closing an individual
Note: Have the gas supply line installed in accordance with local building codes by a qualified installer approved and/or licensed as required by the locality.
Note: Before the first firing of the fireplace, the gas supply line should be purged of any trapped air.
Note: Consult local building regulations to properly size the gas supply line leading to the (Rp 1/2 in.)
Incoming gas line should be piped into the valve compart- ment and connected to the ISO
Note: Gas line MUST be run from right side of fireplace.
WARNING
Fire Risk
Explosion Risk
High pressure will damage valve.
•Disconnect gas supply piping BEFORE pressure testing gas line at test pressures above 60 mbar.
•Close the manual shutoff valve BEFORE pressure testing gas line at test pressures equal to or less than 60 mbar.
Table 1
WARNING
CHECK FOR GAS LEAKS
Fire Risk
Explosion Risk
Asphyxiation Risk
•Check all fittings and connections.
•Do not use open flame.
•After the gas line installation is complete, all connections must be tightened and checked for leaks with a commercially available,
Fittings and connections may have loosened during shipping and handling.
| Natural Gas | Propane | Butane | Natural Gas | ||||
| (G20) | (G31) | (G30) | (G25) | ||||
Inlet Pressure | 20mbar | 37 or 50mbar | 30 or 50mbar | 25mbar | ||||
|
|
|
|
| ||||
Manifold Pressure | 24mbar | 24mbar | 8.7mbar | |||||
|
|
|
|
|
|
|
|
|
Gas Rate | 1.68 | m3 h | .62 | m3 h | .42 | m3 h | 1.68 | m3 h |
| / | / | / | / | ||||
Max.Input (NETCV) | 16.5 kW | 15.0 kW | 13.7kW | 14.0 kW | ||||
|
|
|
|
| ||||
Burner Injector | DMS 25 | DMS 44 | DMS 46 | DMS 25 | ||||
|
|
|
|
| ||||
Pilot Injector | 51 | 30 | 30 | 51 | ||||
|
|
|
|
|
|
|
|
|
Heat & Glo Lifestyle Collection • Dakota | 9 |