Model #

A

B

C

D

in.

36

52

8

16

EL36

914

1321

203

406

mm

in.

42

66

12

20

EL42

1067

1676

305

508

mm

4 in. (102 mm)

 

 

 

minimum between

 

 

 

bottom of fireplace opening

 

 

and finished surface of hearth extension

C

 

 

 

 

 

A

 

 

 

B

 

 

C

 

 

 

 

 

 

 

 

 

D

Figure 11.1 Hearth Extension Dimensions

 

 

Continuous, non-

 

Fireplace

combustible sealant

 

Opening

1/2 in. Micore Hearth

Tile, stone or other

 

Extension (or

non-combustible material

4 in.

equivalent insulation)

 

 

(102 mm) min.

See Table 11.2.

 

 

 

Floor constructed of wood or

2 in. (51 mm) of the Protective

Metal Hearth Strip is required

other combustible material

under the front of the fireplace

Figure 11.2 Hearth Extension Construction

Raised Hearth Extension Framing

WARNING! Risk of Fire. A raised hearth extension built flush with the fireplace opening (Figure 11.3) or less than 4 in. (102 mm) below the fireplace opening requires the fireplace be installed on a non-combustible surface.

The hearth framing must be constructed of non-combus- tible materials (Figure 11.2) and placed on 1/2 in. Micore, or equivalent material (Figure 11.4). When creating the platform, allow for the thickness of the non-combustible finishing materials (Figure 11.5).

IMPORTANT! Hearth extension design must be determined before installation of fireplace.

Noncombustible

Material

Noncombustible

Finishing Material

Noncombustible

Framing Material

1/2 in. Micore

 

 

 

 

 

 

 

 

Protective Metal

Floor

or equivalent

Hearth Strips

 

 

insulation

 

 

 

 

 

 

Figure 11.3 Raised Platform Hearth Extension Detail

Noncombustible

Framing Material1/2 in. Micore or equivalent insulation

Figure 11.4 Raised Platform Hearth Extension-Framing Materials

Heatilator • EL36/EL42 • 4044-132 • Rev V • 11/08

39

Page 39
Image 39
Hearth and Home Technologies EL36 Series, EL42 Series owner manual Raised Hearth Extension Framing, Minimum between