Hearth and Home Technologies GBFL4136I Intellifire Ignition System - continued, sensing rod

Models: GBST4336I GBFL4136I

1 50
Download 50 pages 62.47 Kb
Page 42
Image 42

Intellifire Ignition System - (continued)

Symptom

Possible Cause

Corrective Action

 

 

 

4. Pilot lights but contin-

a. A shorted or loose connection in flame

Verify all connections to wiring diagram in manual. Verify

ues to spark, and main

sensing rod.

connections underneath pilot assembly are tight. Verify

burner will not ignite.

 

connections are not grounding out to metal chassis, pilot

(If the pilot continues

 

burner, pilot enclosure or screen if present, or any other

to spark after the

 

metal object.

pilot flame has been lit,

 

 

b. Poor flame rectification or contaminated

With fixed glass assembly in place, verify that flame is en-

flame rectification has

flame sensing rod.

gulfing flame sensing rod on left side of pilot hood. Flame

not occurred.)

 

sensing rod should glow shortly after ignition. Verify cor-

 

 

 

 

rect pilot orifice is installed and gas inlet is set to pressure

 

 

specifications.

 

 

 

 

c. Module is not grounded.

Verify module is securely grounded to metal chassis of

 

 

appliance. Verify that wire harness is firmly connected to

 

 

the module.

 

 

 

 

d. Damaged pilot assembly or contami-

Verify that ceramic insulator around the flame sensing

 

nated flame sensing rod.

rod is not cracked, damaged, or loose. Verify connection

 

 

from flame sensing rod to white sensor wire. Clean flame

 

 

sensing rod with emery cloth to remove any contaminants

 

 

that may have accumulated on flame sensing rod. Verify

 

 

continuity with a multimeter with ohms set at lowest range.

 

 

Replace pilot if any damage is detected.

 

 

 

 

e. Faulty module.

Turn ON/OFF rocker switch or wall switch to OFF position.

 

 

Remove ignitor wire “I” from module. Place ON/OFF rocker

 

 

switch or wall switch in ON position. If there is no spark at

 

 

“I” terminal module must be replaced. If there is a spark at

 

 

“I” terminal, module is fine.

 

 

 

42

Heatilator • GBST4336I, GBFL4136I • 2135-900 Rev. D • 11/08

Page 42
Image 42
Hearth and Home Technologies GBFL4136I Intellifire Ignition System - continued, Pilot lights but contin, sensing rod