17
Heat & Glo • SL-350TRSI-AUE • 2089-902 Rev. B • 6/06
Figure 18.
WARNING: FAILURE TO REMOVE
INSULATION IN THE SET OF COL-
LARS YOU ARE USING COULD
CAUSE A FIRE.
WARNING: THE REAR FLUE COL-
LAR SEAL CAP MUST REMAIN AT-
TACHED TO THE REAR FLUE COL-
LARS IF THE FLUE SYSTEM IS AT-
TACHED TO THE TOP STARTING
COLLARS. SEE FIGURE 17.
WARNING: YOU MUST LEAVE
THE INSULATION IN PLACE IN
THE SET OF COLLARS YOU ARE
NOT USING.
FLUEING OUT REAR FLUEING OUT TOP
Installing Flue Components
After determining which set of starting collars will be
used (top or rear), follow flueing instructions
accordingly.
Flueing Out the Rear Flue
Remove the rear collar seal cap by cutting the
strap at each end (see Figure 18).
Next, remove the insulation from the rear flue, pull
the heat shield out from outside of the heater.
WARNING: THE TOP FLUE COLLAR
SEAL CAP MUST REMAIN ATTACHED
TO THE TOP FLUE COLLAR IF THE FLUE
SYSTEM IS ATTACHED TO THE REAR
STARTING COLLARS. SEE FIGURE 18.
Flueing Out the Top Flue
Remove the top flue collar cover plate. Remove
the seal cap and both pieces of insulation in the
top collars (see Figure 18). Remove the heat
shield inside the top collars from the outside of
the heater.
!
!
!
!
Insert screwdriver
or similar object
here to remove cap.
CUT
HERE
HEAT
SHIELD
DISCARD
INSULATION
and
HEAT SHIELD
SEAL
CAP
SEAL
CAP
HEAT
SHIELD
INSULATION,
DISCARD
BOTH
PIECES and
HEAT SHIELD
Í