24 Heat & Glo • SL-350TRSI-AUE • 2089-902 Rev. B • 6/06
Figure 32.
NOTE: IF ANY OF THE ORIGINAL
WIRE AS SUPPLIED WITH THE
APPLIANCE MUST BE RE-
PLACED, IT MUST BE REPLACED
WITH TYPE 105 C RATED WIRE.
Figure 33.
BROWN
BROWN
BLUE
BLACK
BLUE
BLACK
(HOT) BROWN
(NEUTRAL) BLUE
BLACK
BLACK
BLUE
BROWN
GREEN/YELLOW
BLOWER
TEMPERATURE
SENSOR SWITCH
240VAC JUNCTION BOX
VARIAB LE
SPEED
CONTROL
BROWN
BLUE
BLACK
BROWN
BLUE
BROWN
BLUE
BLACK
GREEN/YELLOW
STRIPE
GREEN/YELLOWSTRIPE
1.5 BLOWER FAN
These heaters have a factory installed Fan, Elec-
trical Junction Box, Variable Speed Rheostat
Control Switch and Temperature Sensor Switch
for the fan. These components are located be-
hind the lower door.
Use of the fan requires that the Junction Box
(factory installed) be connected to 240 VAC
service before permanently enclosing the heater.
The access hole for connecting the service wires
is found on the right exterior side of the unit.
See Figure 33 for wire connection detail.