OPERATING CAUTIONS
This appliance may exhibit a slight carbon deposition.
Do not place articles on or against this appliance.
Do not use or store flammable materials near this
appliance.
Do not spray aerosols in the vicinity of this appli-
ance while it is in operation.
The DRESS GUARD IS fitted to this appliance to
reduce the risk of fire or injury from burns and no
part of it should be permanently removed. For pro-
tection of young children or the infirm, a secondary
guard is required.
The glass door assembly must be in place and sealed
and the fixed mesh DRESS GUARD must be in place
on the fireplace before the unit can be placed into
safe operation.
Do not use this appliance if any part has been under
water. Immediately call a qualified service techni-
cian to inspect the unit and to replace any part of
the control system and any gas control which has
been underwater.
Do not operate this appliance with the glass door
removed, cracked, or broken. Replacement of the
glass door should be done by a licensed or qualified
person. Do not strike or slam the glass door.
The glass door assembly shall only be replaced as
a complete unit as supplied by the gas fireplace
manufacturer. No substitute materials may be used.
Figure 37.
2.0 OPERATING INSTRUCTIONS
This appliance is a balanced flue heater and is designed
to operate with all combustion air being siphoned from
the outside of the building and all exhaust gases ex-
pelled to the outside of the building.
WARNING: THIS UNIT IS NOT FOR USE
WITH SOLID FUEL.
The control system for this model is an electronic sys-
tem which includes a gas control valve, pilot, thermo-
couple, ignitor and electronic ignition module. The con-
trols are located in the lower compartment behind the
lower door, and access is gained by lifting the door
up. See Figure 1.
WARNING: DO NOT CONNECT 240 VAC
TO THE GAS CONTROL VALVE OR CON-
TROL WIRING SYSTEM OF THIS UNIT.
When lit for the first time, the appliance will emit a slight
odor for an hour or two. This is due to paint and lubri-
cants used in the manufacturing process. Additionally,
for the first few minutes after each lighting, vapor may
condense and fog the glass and the flames may be blue.
After a few minutes this moisture will disappear and within
15-30 minutes the flames should become yellow.
The heater may produce a noise, caused from metal
expansion and contraction as it heats up and cools down.
This noise is similar to one that a furnace or heat duct
may produce and does not affect the operation or lon-
gevity of the heater.
IGNITION
MODULE
(6V)
ON/OFF
WALL SWITCH
VALVE
FLAME SPARKER/
SENSOR
ANT.
REMOTE
CONTROL
HOTNEUTRAL
GROUND
BATTERY PORT
VALVE
PILOT
IGNITION MODULE
6VDC
ON/OFF
SWITCH
THERMOCOUPLE
BLOCK
(CONNECTED TO
BACK OF VALVE)
GAS LINE
CONNECTED TO
BACK OF VALVE
PLUG IN