Heat & Glo • SL-750TRS-IPI-E, SL-550TRS-IPI-E, SL-350TRS-D, SL-350TRS-IPI • 2120-900 Rev. D • 6/07 23
3. Rear Vent - Horizontal Termination - (continued)
Figure 5.13
Figure 5.14
Three Elbows
H1 Maximum V1 Minimum H2+ H3H1+ H2+ H3 Maximum
1-1/2 ft. 457 mm Back to Back
Elbows 1 ft. 305 mm 2-1/2 ft. 762 mm
3-1/2 ft. 1.1 m 1 ft. 305 mm 2 ft. 610 mm 5-1/2 ft. 1.7 m
5-1/2 ft. 1.7 m 2 ft. 610 mm 4 ft. 1.2 m 9-1/2 ft. 2.9 m
7-1/2 ft. 2.3 m 3 ft. 914 mm 6 ft. 1.8 m 13-1/2
ft. 4.1 m
H1 Maximum = 7-1/2 ft. (2.3 m)
H1 + H2 + H3 Maximum =13-1/2 ft. (4.1 m)
V1 + H1 + H3= 40 ft. (12.2 m)
V1
H1
One Elbow
V1 Minimum H1 Maximum
Elbow Only 1-1/2 ft. 457 mm
1 ft. 305 mm 3-1/2 ft. 1.1 m
2 ft. 610 mm 5-1/2 ft. 1.7 m
3 ft. 914 mm 7-1/2 ft. 2.3 m
H1 Maximum = 7-1/2 ft. (2.3 m)
V1 + H1 Maximum = 40 ft. (12.2 m)
4. Rear Vent - Vertical Termination
Note: Use DVP Series
components only.
Note: Use DVP Series
components only.
INSTALLED
HORIZONTALLY
H3
H1
H2
V1