Heat & Glo • SL-750TRS-IPI-E, SL-550TRS-IPI-E, SL-350TRS-D, SL-350TRS-IPI • 2120-900 Rev. D • 6/0724
Figure 5.15
Two Elbows
H1 Maximum V1 Minimum H2H1 + H2 Maximum
1-1/2 ft. 457 mm Back to Back
Elbows 1 ft. 305 mm 2-1/2 ft. 762 mm
3-1/2 ft. 1.1 m 1 ft. 305 mm 3 ft. 914 mm 6-1/2 ft. 2.0 m
5-1/2 ft. 1.2 m 2 ft. 610 mm 5 ft. 1.5 m 10-1/2 ft. 3.2 m
7-1/2 ft. 2.3 m 3 ft. 914 mm 7 ft. 2.1 m 14-1/2ft. 4.4 m
H1 Maximum = 7-1/2 ft. (2.3 m)
V1 + V2 + H1 + H2 Maximum = 40 ft. (12.2 m)
4. Rear Vent - Vertical Termination - (continued)
H1+ H2 Maximum V1 Minimum
1/2 ft. 152 mm Back to Back Elbows
2-1/2 ft. 762 mm 1 ft. 305 mm
4-1/2 ft. 1.4 m 2 ft. 610 mm
6-1/2 ft. 2.0 m 3 ft. 914 mm
H Maximum = 6-1/2 ft. (2 m)
V1 + H1 + H2 Maximum = 40 ft. (12.2 m)
Figure 5.16
Three Elbows
Note: Use DVP Series
components only.
Note: Use DVP Series
components only.
INSTALLED
HORIZONTALLY H1
H2
V1
V2
V1
H2
H1